14

Maintenance

Brush Cleaning And Maintenance

After each session of carpet cleaning, the brushes
and the brush housing should be cleaned. Before
cleaning or changing the brushes, always unplug the
machine from the power supply.

Brushes are removed without tools. After handle is in
locked position, tilt the machine back and rest on
handle. To release brush from spring clip pull spring
clip away from brush end cap. Lift brush out of
machine.

The brushes may be soaked in warm or hot water
using mild detergent, and then rinsed with warm
water.

NOTE: Brushes with crushed bristles can often be
restored to original condition by soaking in hot
water.

Keep brushes clean and free from debris. Rotate
brushes after every use as this will increase the life
span of the brushes and ensure even wear.

Before reinstalling brushes, clean out machine brush
housing and hopper by wiping with a clean damp
cloth.

Motor Replacement & Grooved Belt
Tensioning

1. Disconnect machine power supply.

2. Detach quick disconnect hose from top of

solution tank. (Deluxe Only)

3. Remove elastic straps and solution tank. (Deluxe

Only)

4. Remove two dome screws and dome assembly.

5. Remove the circuit breaker boot and push the

circuit breaker clear of cover.

NOTE: All directions mentioned in this manual are
from the operator’s point of view.

6. Mark left and right on the lift cams.

7. Remove the two cam bolts. This will also free the

lift cams.

NOTE: There are four plastic bushings that the
handle pivots on, leave them on the motor clamps.

8. Remove the handle assembly.

9. Unscrew the wiring grommet from the main

cover, and set retaining bracket and screw aside.

10. Remove the front and back screws and move the

main cover to the side.

NOTE: The handle assembly and cover are still
attached to the frame by wiring. Be careful not to
pinch wiring when reassembling.

11. Remove the (2) plastic finger guards.

12. Mark the tension set screws for reference when

reassembling.

DOME

COVER

CIRCUIT BREAKER
& BOOT

WIRING GROMMET

LIFTING CAM

LIFTING CAM

LEFT

RIGHT

LEFT SIDE

RIGHT SIDE

LIFT BRACKET

MOTOR CLAMP

MOTOR

PLASTIC FINGER
GUARD (2)