Operations technical specifications – Prochem ProCaps Deluxe User Manual

Page 9

Advertising
background image

9

Operations

Technical Specifications

120V

230 V

Special Notes:

NOTE: This appliance is not intended for use by persons (including children) with reduced physical, sensory
or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or
instruction concerning use of the appliance by a person responsible for their safety. Children should be
supervised to ensure that they do not play with the appliance.

ITEM

DIMENSION/CAPACITY

Electrical

120V

Nominal Power

0.5 HP

Rated Amperage

7 Amps

Brush Width

17 - 16.5" (430 - 420 mm)

Brush RPM

470 RPM

Wheels

3 inches (75 mm) non-marking grey

Dimensions - Weight
- Weight - Deluxe

48 lbs. (22 kg)
56 lbs. (25 kg)

Dimensions - Height with handle

45.5" (1.16 m)

Dimensions - Depth

16 inches (0.4 m)

Power Cord

40 feet (12.2 m)

Solution Tank Volume - Deluxe

2 gallon

Pump Pressure - Deluxe

50 psi

Solution Flow - Deluxe

0.1 gpm

Spray Jet Size - Deluxe

.010

ITEM

DIMENSION/CAPACITY

Electrical

230V

Nominal Power

0.5 HP

Rated Amperage

4 Amps

Brush Width

17 - 16.5" (430 - 420 mm)

Brush RPM

470 RPM

Wheels

3 inches (75 mm) non-marking grey

Dimensions - Weight
- Weight - Deluxe

48 lbs. (22 kg)
56 lbs. (25 kg)

Dimensions - Height - with handle

45.5" (1.16 m)

Dimensions - Depth

16 inches (0.4 m)

Power Cord

40 feet (12.2 m)

Solution Tank Volume - Deluxe

2 gallon

Pump Pressure - Deluxe

50 psi

Solution Flow - Deluxe

0.1 gpm

Spray Jet Size - Deluxe

.010

86269870 CARPET MAINTAINER

The sound pressure level at the operator's ear was
measured to be 67.7dBA. This was a nearfield,
broad-band measurement taken on a carpeted floor.
This appliance contains no possible source of impact
noise. The instantaneous sound pressure level is
below 63 Pa.

The weighted root mean square acceleration at the
operator's arms was measured to be below 2.5m/s2.
This was a tri-axial, third-octave-band measurement
made during normal operation on a composite tile
floor. The measurement and related calculations
were made in accordance with ISO 5349-1.