BLOWBACK

BLOWBACK Indicator

The BLOWBACK indicator lights when the air solenoid is open.


MATERIAL "B"

MATERIAL “B” Indicator

The MATERIAL “B” indicator lights when the Material B port is open.


5-4 Starting Up the Hopper Loader for the First Time Using the
Series One Plus Controller

Non-Proportioning Models

1. Insert the pickup wand into the material supply.

2. Turn on the compressed air to the hopper loader.

3. Apply power to the controller.

Note: Press and hold the

CLEAR

UP

key and

DOWN

key together

simultaneously while applying power to restore all factory
defaults.

As the controller powers up, the screen displays in succession:

PLUS for three seconds
• the software version number n.nn
• the standby mode display.

4. Press

the

S

START/STOP

START/STOP/SELECT/SET key to start the

hopper loader.

The vacuum motor conveys material until the proximity sensor
indicates the hopper loader is full or the factory-pre-set default
maximum vacuum time of sixty seconds passes, whichever comes
first. The VACUUM and MATERIAL “A” LEDs light and the
LED display shows the elapsed conveying time.