4 configuration parameters setup, 2 setting installed screw number – Sterlco SF1000 Gravimetric Additive Feeder User Manual
Page 16

16
4.4 Configuration Parameters setup
4.4.1 Set general working configuration parameter values - dosing screw type, operation
mode and hopper Max/Min Fill - before entering the specific job parameters.
While in Main screen:
Press
key to enter Maintenance screen
Press <
4
> key to enter Parameters screen
Use the following setting procedure to enter or modify any of the 4 parameters:
<SET> Select desired parameter. The parameter value field will be marked.
Enter (by keyboard) desired new value, and press <ENT> to make new value
active. The next parameter will be selected.
If you want to switch to next parameter without modifying the present value, press
<SET> without pressing <ENT>
Pressing <ESC> twice at any time will return you to the Main Screen
4.4.2 Setting installed screw number
Each dosing screw is marked by its identifying number:
"0"
– Micro capacity
2 pellet/shot to 0.2 kg/h
"1" - Small capacity
0.1
– 3.5 kg/h*
"2"
– Medium capacity
0.4-10 kg/h
"3"
– High Capacity
0.6
– 20 kg/h
"4"
– Extra high capacity 1.0 – 35 kg/h
*There are two types of screw #1:
"1.1" Standard low capacity
"1.0" Special low capacity
To change screw number, return to Parameters screen, select the Screw line and
set the new installed Screw number (using setting procedure described in 4.4.1)