Operator level 1, 1 level 1 operator parameters, Operator level 2 – Sterlco SEU Series Economical Water TCU User Manual

Page 8: To enter level 2, To return to level 1, Level 2 parameters, Level 1 operator parameters, 1 to enter level 2, 2 to return to level 1, 3 level 2 parameters

Advertising
background image

3200

Series

8 ACS 3216 Operators Manual

4. Operator Level 1

4.1.1

Level 1 Operator Parameters

A minimal list of parameters are available in operator Level
1 which is designed for day to day operation. Access to
these parameters is not protected by a pass code.

Press

to step through the list of parameters.

The

mnemonic of the parameter is shown in the lower display.
After five seconds a scrolling text description of the
parameter appears.

The value of the parameter is shown in the upper display.

Press

or

to adjust this value. If no key is

pressed for 30 seconds the controller returns to the HOME
display

The parameters that appear depend upon the functions
configured. They are:-

Home List

Parameter
Mnemonic

Scrolling Display

and Description

Alterability

WRK.OP WORKING

OUTPUT

The active output
value

Read only.

Appears when the
controller is in AUTO or
OFF mode.

In a motorised valve
controller (option VC or
VP) this is the ‘inferred’
position of the valve

A.TUNE

AUTO TUNE

Activate Auto
Tune Of PID
Loop.

Alterable

SP1

SETPOINT 1

Alterable

SP2 SETPOINT

2

Alterable

T.REMN TIME

REMAINING
Time to end of set
period

Read only

0:00 to 99.59 hh:mm or
mm:ss

DWELL SET

TIME

DURATION
Timer set time

Alterable. Only shown if
timer (not programmer)
configured.

DEC.P DECIMAL

POINT

Read only

UNITS DISPLAY

UNITS

Read Only

PB PROPORTIONAL

BAND

Alterable

TI

INTEGRAL

TIME

Alterable

TD DERIVATIVE

TIME

Alterable

R2G RELATIVE

COOL GAIN

Read Only

OP.HI OUTPUT

HIGH LIMIT

Read Only

ADDR COMMS

ADDRESS

Read Only

5. Operator Level 2

Level 2 provides access to additional parameters. Access to
these is protected by a security code.

5.1

To Enter Level 2

1.

From any display press and hold



.

2.

After a few seconds the display will
show:-

3.

Release



.

(If no button is pressed for about 45 seconds the display
returns to the HOME display)

4.

Press

or

to

choose

Lev 2 (Level 2

5.

After 2 seconds the

display will show:-

6.

Press

or

to enter the

pass code. = ‘

101’

If an incorrect code is entered the controller reverts to
Level 1.

5.2

To Return to Level 1

1.

Press and hold



2.

Press

to select

LEv 1

The controller will return to the level 1 HOME display.
Note: A security code is not required when going from a
higher level to a lower level.

5.3

Level 2 Parameters

Press

to step through the list of parameters.

The

mnemonic of the parameter is shown in the lower display.
After five seconds a scrolling text description of the
parameter appears.

The value of the parameter is shown in the upper display.

Press

or

to adjust this value. If no key is

pressed for 30 seconds the controller returns to the HOME
display

Backscroll is achieved when you are in this list by pressing

while holding down

.

The following table shows a list of parameters available in
Level 2.

Advertising