Setting & controlling your chiller – Teco US TR5-60 User Manual

Page 9

Advertising
background image

Page 16

Page 17

Silent Mode

Press “SILENT”

1

when the chiller is on. Silent mode slows the

ventilation fan, causing the chiller to become quieter. Press “SILENT”
again to turn silent mode off.

Note: We strongly suggest using the silent function sparingly because it
reduces the cooling capability of the chiller considerably.

UV Sterilizer

Press “UV”

1

If the optional UV sterilizer is installed, pressing the

UV button will activate the sterilizer. The green led light on the UV will
illuminate to indicate the UV light is on.

Note: If the optional UV kit is not installed the light will flash on and off
UV Sterilizer is not availble on the TR5.

Switching from Fahrenheit to Centigrade

Press and hold both up

1

and down arrows simultaneously

for 10 seconds.

The display will automatically change from degrees

Fahrenheit to degrees Centigrade. To change back, repeat process.

Changing Temperature Display

The chiller reads the temperature from the water passing

through it, a thermometer reading directly from the tank may
be reading a different temperature depending on your specific
setup. Use this function if you would like to match the chiller’s
thermometer to a separate thermometer.

Press and hold “SET” for 10 seconds.

1

The display will show a value of 1 or 1.5 (do not change this setting)

Press “SET” again

2

The water temperature (not the set point) will be displayed.

Push up or down arrow to change temperature.

3

After five seconds, the setting is entered into memory and the display

will return to full brightness. The unit will now function normally with the
new calibrated temperature.

TR

10

TR

15

TR

20

TR

10

TR

15

TR

20

TR

30

TR

60

ALL MODELS

ALL MODELS

Setting & Controlling Your Chiller

Setting & Controlling Your Chiller

Setting Temperature

The unit has been factory set at 77˚F, to change this setting follow the
steps outlined below.

Turn on the chiller.

1

The power switch is located on the side of

the chiller near the power cord, the TR30 and TR60’s switch is
located on the control panel. Once power has been turned on the
chiller will begin to operate after approximately five seconds. The
display will show the current temperature of the aquarium water
passing through the chiller.

Push “SET”

2

The display will change from the current

temperature to the set temperature.

Push up or down arrow to change temperature.

3

Using the up and down arrows, set the controller to the desired
water temperature. The temperature will be set automatically
five seconds after you release the button.

Once the chiller reaches the set temperature the unit will enter

4

stand-by mode; both the lights above the temperature display will
be off. When the temperature changes the chiller or heater will
cycle on as appropriate.

Note: Illuminated green LED indicates chiller is operational, illuminated red LED
indicates heater is operational. (For units with installed heaters).

TR

5

TR

10

TR

15

TR

20

TR

30

TR

60

Control Panel

All Teco Seachill models share the
same control functionality. The
following directions apply to all models,
with exceptions for Silent Mode, UV
Sterilizer, and Heater for models that do
not have those functions.

ALL MODELS