Cancelling programmes, Self cancelling override, Specifications – Timeguard EL17 User Manual
Page 11

2
10
6. Cancelling Programmes
Any ON/OFF programme can be cancelled by clearing its ON and OFF time.
Follow step 5 and when into the ON or OFF programme to be cancelled press
the <Change> button until the hour digits show --:
then press the <Program> button to clear the
programme. The display will show the hour and
minute digits and ON or OFF flashing.
(Note: Monday shown as an example of days set).
Self Cancelling Override
To change the output status from ON to OFF or vice versa during normal operation
press the <Change> button. The output status will change and indicate override is in
operation by flashing.
1 2 3 4 5 6 7
●
Specifications
1. Confirms to latest directives.
2. Contacts:
Silver Cadmium Oxide. Single pole change over.
3. Permissible Loads: 16A Resistive
6A
At 0.4 power factor inductive
10A Filament lamps
*500W Fluorescent lighting with or without power factor
correction capacitors (4μF per 65W tube)
1 h.p. Motor
For other loads refer to Technical Service on 020 8450 0515
*This load with power factor correction capacitors is not
recommended for normally closed contacts.
4. Panel Cut Out:
67mm square with 2.5mm radius corners.
5. Battery Back-up: 1000 hours by factory fitted rechargeable battery.
6. Operating ambient temperature: -10°C to 40°C. Upper limit can be
increased for loads less than 16A –
refer to Technical Service.
7. Operating Voltage:
220 – 240V AC 50Hz.