Timeguard DSS User Manual

Page 7

Advertising
background image

6

7

Fig 6 –

Replacement Delay Switches fitted to circuit shown in fig. 4

Fig 7 –

Replacement Delay Switches fitted to circuit shown in fig. 5

A DS1 and two DSS’s can be used to replace these switches for both

wiring systems to give time delayed momentary switching at all

three switch locations. The DS1 should not be located at a former

intermediate switch location. The circuits for both wiring systems

with the replacement switches are shown in figs 6 and 7. No wiring

alterations are required but to establish which wires are connected

to which terminals the wires must be identified and traced. An in-line

connector is required for the Strapping Cable System to provide

continuity for the SL connection.

In keeping with BS schematic code wires shown in direct cross over

(i.e. +) are not connected electrically.