43 out4 setting mode (set8), Out5 setting mode (set9), Out6 setting mode (set10) – TOHO ELECTRONICS TTM200 User Manual

Page 43: Out7 setting mode (set11)

Advertising
background image

43

Out4 setting mode (set8)

toho

modbus

Screen

character

Name

Command Remark

Identifier

Absolute

(DEC)

Relative (hex)

O4F

42049

0800

o4F Set an out4 destination

RWLB

E41

42051

0802

E4F1 Set an out4 event function 1

RWLB

E4H

42053

0804

E4H Set an out4 event upper limit

RWLB

E4L

42055

0806

E4L Set an out4 event upper limit

RWLB

E4C

42057

0808

E4C Set an out4 event sensitivity

RWLB

E4T

42059

080A

E4t Set an out4 event delay timer

RWLB

E42

42061

080C

E4F2 Set an out4 event function 2

RWLB

E43

42063

080E

E4F3 Set an out4 event function 3

RWLB

E44

42065

0810

E4F4 Set an out4 event function 4

RWLB

E4P

42067

0812

E4P Set an out4 event polarity

RWLB


Out5 setting mode (set9)

toho

modbus

Screen

character

Name

Command Remark

Identifier

Absolute

(DEC)

Relative (hex)

O5F

42305

0900

o5F Set an out5 destination

RWLB

E51

42307

0902

E5F1 Set an out5 event function 1

RWLB

E5H

42309

0904

E5H Set an out5 event upper limit

RWLB

E5L

42311

0906

E5L Set an out5 event upper limit

RWLB

E5C

42313

0908

E5C Set an out5 event sensitivity

RWLB

E5T

42315

090A

E5t Set an out5 event delay timer

RWLB

E52

42317

090C

E5F2 Set an out5 event function 2

RWLB

E53

42319

090E

E5F3 Set an out5 event function 3

RWLB

E54

42321

0910

E5F4 Set an out5 event function 4

RWLB

E5P

42323

0912

E5P Set an out5 event polarity

RWLB


Out6 setting mode (set10)

toho

modbus

Screen

character

Name

Command Remark

Identifier

Absolute

(DEC)

Relative (hex)

O6F

42561

0A00

o6F Set an out6 destination

RWLB

E61

42563

0A02

E6F1 Set an out6 event function 1

RWLB

E6H

42565

0A04

E6H Set an out6 event upper limit

RWLB

E6L

42567

0A06

E6L Set an out6 event upper limit

RWLB

E6C

42569

0A08

E6C Set an out6 event sensitivity

RWLB

E6T

42571

0A0A

E6t Set an out6 event delay timer

RWLB

E62

42573

0A0C

E6F2 Set an out6 event function 2

RWLB

E63

42575

0A0E

E6F3 Set an out6 event function 3

RWLB

E64

42577

0A10

E6F4 Set an out6 event function 4

RWLB

E6P

42579

0A12

E6P Set an out6 event polarity

RWLB


Out7 setting mode (set11)

toho

modbus

Screen

character

Name

Command Remark

Identifier

Absolute

(DEC)

Relative (hex)

O7F

42817

0B00

o7F Set an out7 destination

RWLB

E71

42819

0B02

E7F1 Set an out7 event function 1

RWLB

E7H

42821

0B04

E7H Set an out7 event upper limit

RWLB

E7L

42823

0B06

E7L Set an out7 event upper limit

RWLB

E7C

42825

0B08

E7C Set an out7 event sensitivity

RWLB

E7T

42827

0B0A

E7t Set an out7 event delay timer

RWLB

E72

42829

0B0C

E7F2 Set an out7 event function 2

RWLB

E73

42831

0B0E

E7F3 Set an out7 event function 3

RWLB

E74

42833

0B10

E7F4 Set an out7 event function 4

RWLB

E7P

42835

0B12

E7P Set an out7 event polarity

RWLB

Advertising