UEi Test Instruments MCP4 User Manual

Page 3

Advertising
background image

Measuring Temperature
Set the MCP4 to the “R x 10 0 / TEMP” range. Insert both of the black plugs
on the temperature probe into the “OHM” input jacks on the MCP4.
Adjust the green “OHM ADJ” control on the left side of the instrument
until the pointer is set on the green numeral 0.

NOTE: If this adjustment cannot be made refer to the “MAINTENANCE”
section

To make the temperature measurement, remove one of the black
t e m p e rature probe plugs from the input jack and insert the red
t e m p e rature probe plug. The measured temperature will be read
directly from the blue temperature scale on the scale plate.

M a i n t e n a n c e

Periodic Service

WARNING!

Repair and service of this instrument is to be performed by qualified
personnel only. Improper repair or service could result in physical
degradation of the meter. This could alter the protection from
electrical shock and personal injury this meter provides to the
operator. Perform only those maintenance tasks that you are
qualified to do.

These guidelines will help you attain long and reliable service from
your meter:

• Calibrate your meter annually to ensure it meets original

performance specifications

• Keep your meter dry. If it gets wet, wipe dry immediately.

Liquids can degrade electronic circuits

• Whenever practical, keep the meter away from dust and dirt

that can cause premature wear

• Although your meter is built to withstand the rigors of daily use,

it can be damaged by severe impacts. Use reasonable caution
when using and storing the meter

Cleaning
Periodically clean your meter’s case using a damp cloth. DO NOT use
abrasive, flammable liquids, cleaning solvents, or strong detergents as
they may damage the finish, impair safety, or affect the reliability of the
structural components.

Clean the input terminals as follows:

1. Turn the meter off and remove all test leads.

2. Shake out any dirt that may be in the terminals.

3. Soak a new swab with alcohol and work the swab around in

each terminal.

Operating Instructions

Measuring AC Current
When measuring current, always be sure the “SEL ECTOR” switch is set
to the appropriate AMP range. When in doubt, always use the highest
current range first. The switch can always be reset to a lower range for a
more precise reading. AC current measurements are made on the red
A MP scales on the scale plate.

Clamp the jaw of the MCP4 around a single circuit wire.
NOTE: Clamp only one wire at a time for measurement. If two or more
wires are clamped together, the tester will not read.

If the measured value on the meter scale is less than the full scale value
of the next lower range, reset the “SEL ECTOR” switch to the lower ra n g e
for a more accurate reading.

Slide P OINTER LOCK switch toward the right to lock the pointer at its
i n d i cating point when readings must be made in a confined or difficult-to-
read loca t i o n .

Measuring AC Voltage
When measuring voltage be sure the “SEL ECTOR” switch is set to the
appropriate Volt range. When in doubt, always use the highest Volt ra n g e
first. The switch can always be set to a lower range for a more precise
reading. AC voltage measurements are made on the red Volt sca l e s .

Insert the red and black test leads into the “VOLT” input jacks. Connect
the two test leads to the circuit under test.

Measuring DC Voltage
The MCP4 has one DC Volt range which can measure up to 75 Volts.
DC Voltage is read on the red 750 scale and divided by 10. Observe the
proper polarity in the voltage input jacks. Red test lead to “+”, black test
lead to “-” .

Measuring Resistance

WARNING!

Remove all power to the circuit under test when making resistance
measurements. If any voltage is present in the test circuit an erroneous
reading will result and the MCP4 fuse may open.

Insert the red and black plug ends of the test leads into the “Ω
input jacks.

Select the resistance range to be used.

Touch the free ends of the test leads together. The pointer will swing to
the right hand side of the scale. Adjust the green “OHM ADJ” control
on the left side of the instrument until the pointer is set on the green
numeral 0.
NOTE: If this adjustment cannot be made refer to the “MAINTENANCE”
section. Re-zero the MCP9A each time that the tester is used for making
resistance measurements.

To make the resistance measurement, connect the free ends of the test
leads across the element to be measured. The measured resistance
value will be the green numeral indicated on the “OHMS” scale.

MCP4-MAN