UEi Test Instruments DL235 User Manual

Page 10

Advertising
background image

WARNING!

Under no circumstances should you expose batteries to extreme heat or
fire as they may expose and cause injury.

7. Place a fresh 9V battery in the battery clip.

8. Reassemble the meter.

S p e c i f i c a t i o n s

Accuracy is given as ± ([% of reading] + [number of least significant
digits]) at 18˚C to 28˚C with relative humidity up to 80%, for a period
of one year after calibration.

AC Current
RMS Amperes

*1

*1. Sine wave, measured with conductor centered at alignment marks and battery life indication greater than 40 hours
on meter power up.

*2. RMS MIN/MAX: ADD 10 counts.
*3. 1A and above, 30Hz - 45Hz.
*4. AVG only, 2.5A and above RMS MIN/MAX: Add 2% of reading.

Instantaneous Amperes (Crest Mode)

**1

**1. Same as *1
**2. Same as *3
**3. 2.5A and above.

DL235-MAN

P. 9

Range

Resolution

Accuracy

*2

±(3% + 20 dgts)

45Hz - 65Hz

0.30 to 39.99A

0.01A

±(4% + 30 dgts)

30Hz - 45Hz

*3

(40A Scale)

±(4% + 30 dgts)

65Hz - 1KHz

±(8% + 30 dgts)

20Hz - 30Hz

*4

±(3% + 2 dgts)

45Hz - 65Hz

0.30 to 399.9A

0.1A

±(4% + 3 dgts)

30Hz - 45Hz

*3

(400A Scale)

±(4% + 3 dgts)

65Hz - 1KHz

±(8% + 3 dgts)

20Hz - 30Hz

*4

±5%

45Hz - 65Hz

400 to 700A

1A

±7%

30Hz - 45Hz

*3

(400A Scale)

±7%

65Hz - 1KHz

Not Specified

20Hz - 30Hz

*4

Range

Resolution

Accuracy

*2

±(3% + 30 dgts)

45Hz - 65Hz

0.4 to 39.99A

0.2A

±(4% + 30 dgts)

30Hz - 45Hz

*2

(40A Scale)

±(4% + 30 dgts)

65Hz - 1KHz

±(8% + 40 dgts)

20Hz - 30Hz

*3

±(3% + 3 dgts)

45Hz - 65Hz

0.4 to 399.9A

2A

±(4% + 3 dgts)

30Hz - 45Hz

*2

(400A Scale)

±(4% + 3 dgts)

30Hz - 45KHz

±(4% + 4 dgts)

20Hz - 30Hz

*3

±3%

45Hz - 65Hz

400 to 599A

4A

±4%

30Hz - 45Hz

*2

(400A Scale)

±4%

65Hz - 1KHz

±4%

20Hz - 30Hz

*3

±7%

45Hz - 65Hz

600 to 999A

4A

±7%

30Hz - 45Hz

*2

(400A Scale)

±7%

65Hz - 1KHz

±7%

20Hz - 30Hz

*3

Frequency

***1

***1. Same as *1

With current autorange: Trigger Level, 5 Hz to 1500 Hz,

0.7A RMS or more, 1/2 peak current

With manual ranging:

Trigger Threshold, 10 Hz to 1000 Hz
40A Range - 6A RMS or more will trigger
400A Range - 40A RMS or more will trigger.

DC Current

AC Voltage (True RMS)/DC Voltage

AC Voltage: Common Mode Rejection Ratio: >80dB, dc to 60Hz
DC Voltage: Normal Mode Rejection Ratio: >11dB at 50Hz or 60Hz

Common Mode Rejection Ratio: >84dB at dc, 50Hz or 60Hz

Resistance

Continuity Check

Range

Resolution

Accuracy

0.5 to 999.9 Hz

0.1 Hz

±(0.2% + 3 dgts)

1000 to 9999 Hz

1 Hz

±(0.2% + 3 dgts)

Range

Resolution

Accuracy

0.30 to 39.99A

0.01A

±(2% + 30 dgts)

0.3 to 399.9A

0.1A

±(2% + 10 dgts)

400 to 700A

1A

Accuracy

Range

Resolution

AC Voltage

DC Voltage

45 Hz to 65 Hz 45 Hz to 1 KHz

0 to 39.99V

0.01V

0 to 399.9V

0.1V

±(1.0% +3)

±(2.5% +5)

±(1.0% +3)

0 to 750V

1V

±(1.5% +5)

±(1.5% +5)

Range

Resolution

Accuracy

0 to 399.9Ω

0.1Ω

±(1.0% + 10)

0 to 3.999Ω

±(0.1% + 3)

Range

Continuity Beeper

400Ω

Approx. <35Ω

Advertising