WARNING!
Under no circumstances should you expose batteries to extreme heat or
fire as they may expose and cause injury.
7. Place a fresh 9V battery in the battery clip.
8. Reassemble the meter.
S p e c i f i c a t i o n s
Accuracy is given as ± ([% of reading] + [number of least significant
digits]) at 18˚C to 28˚C with relative humidity up to 80%, for a period
of one year after calibration.
AC Current
RMS Amperes
*1
*1. Sine wave, measured with conductor centered at alignment marks and battery life indication greater than 40 hours
on meter power up.
*2. RMS MIN/MAX: ADD 10 counts.
*3. 1A and above, 30Hz - 45Hz.
*4. AVG only, 2.5A and above RMS MIN/MAX: Add 2% of reading.
Instantaneous Amperes (Crest Mode)
**1
**1. Same as *1
**2. Same as *3
**3. 2.5A and above.
DL235-MAN
P. 9
Range
Resolution
Accuracy
*2
±(3% + 20 dgts)
45Hz - 65Hz
0.30 to 39.99A
0.01A
±(4% + 30 dgts)
30Hz - 45Hz
*3
(40A Scale)
±(4% + 30 dgts)
65Hz - 1KHz
±(8% + 30 dgts)
20Hz - 30Hz
*4
±(3% + 2 dgts)
45Hz - 65Hz
0.30 to 399.9A
0.1A
±(4% + 3 dgts)
30Hz - 45Hz
*3
(400A Scale)
±(4% + 3 dgts)
65Hz - 1KHz
±(8% + 3 dgts)
20Hz - 30Hz
*4
±5%
45Hz - 65Hz
400 to 700A
1A
±7%
30Hz - 45Hz
*3
(400A Scale)
±7%
65Hz - 1KHz
Not Specified
20Hz - 30Hz
*4
Range
Resolution
Accuracy
*2
±(3% + 30 dgts)
45Hz - 65Hz
0.4 to 39.99A
0.2A
±(4% + 30 dgts)
30Hz - 45Hz
*2
(40A Scale)
±(4% + 30 dgts)
65Hz - 1KHz
±(8% + 40 dgts)
20Hz - 30Hz
*3
±(3% + 3 dgts)
45Hz - 65Hz
0.4 to 399.9A
2A
±(4% + 3 dgts)
30Hz - 45Hz
*2
(400A Scale)
±(4% + 3 dgts)
30Hz - 45KHz
±(4% + 4 dgts)
20Hz - 30Hz
*3
±3%
45Hz - 65Hz
400 to 599A
4A
±4%
30Hz - 45Hz
*2
(400A Scale)
±4%
65Hz - 1KHz
±4%
20Hz - 30Hz
*3
±7%
45Hz - 65Hz
600 to 999A
4A
±7%
30Hz - 45Hz
*2
(400A Scale)
±7%
65Hz - 1KHz
±7%
20Hz - 30Hz
*3
Frequency
***1
***1. Same as *1
With current autorange: Trigger Level, 5 Hz to 1500 Hz,
0.7A RMS or more, 1/2 peak current
With manual ranging:
Trigger Threshold, 10 Hz to 1000 Hz
40A Range - 6A RMS or more will trigger
400A Range - 40A RMS or more will trigger.
DC Current
AC Voltage (True RMS)/DC Voltage
AC Voltage: Common Mode Rejection Ratio: >80dB, dc to 60Hz
DC Voltage: Normal Mode Rejection Ratio: >11dB at 50Hz or 60Hz
Common Mode Rejection Ratio: >84dB at dc, 50Hz or 60Hz
Resistance
Continuity Check
Range
Resolution
Accuracy
0.5 to 999.9 Hz
0.1 Hz
±(0.2% + 3 dgts)
1000 to 9999 Hz
1 Hz
±(0.2% + 3 dgts)
Range
Resolution
Accuracy
0.30 to 39.99A
0.01A
±(2% + 30 dgts)
0.3 to 399.9A
0.1A
±(2% + 10 dgts)
400 to 700A
1A
Accuracy
Range
Resolution
AC Voltage
DC Voltage
45 Hz to 65 Hz 45 Hz to 1 KHz
0 to 39.99V
0.01V
0 to 399.9V
0.1V
±(1.0% +3)
±(2.5% +5)
±(1.0% +3)
0 to 750V
1V
±(1.5% +5)
±(1.5% +5)
Range
Resolution
Accuracy
0 to 399.9Ω
0.1Ω
±(1.0% + 10)
0 to 3.999Ω
1Ω
±(0.1% + 3)
Range
Continuity Beeper
400Ω
Approx. <35Ω