LCD Display Functional Description

14. Soft Cre s t : Select “SOFT” for a running 3-second average, or

CREST half cycle peak amperes.

15. AC/DC: Selects AC or DC mode.

16. Lever: Opens and closes clamp jaws.

17. Record: Displayed (blinking) when “MIN/M AX / AV G“ values are

being recorded. Duration of RE CO RD is limited by battery life.

18. MIN/MAX/AVG: Displayed in “REC ORD” mode by pressing

MIN/M AX” push-button.

19.

: Displayed when “HOL D” push-button has been pressed.

20.

: Displayed when “ “ push-button has been pressed.

21. Soft: Displayed when current flow readings or Hz or V readings are

softened out over 3-second interv a l s .

22. KΩVHz: Displayed when measuring ohms or voltage or frequency.

23. Peak: Displayed when current flow readings are in half-cycle

peak amperes (CRES T m o d e ) .

24. RMS: Displayed when current reading is in amperes rms.

25. Off-Scale Arrow: Displayed when bar graph pointer is off sca l e .

26. Dual: Displayed when measuring frequency in digital and

amperes in bar graph simultaneously.

27. A: Displayed when meter is measuring amperes.

28. Digital Display: Displays 3999 counts, with two decimal points

relative to the two ranges. But, displays 9999 counts in frequency
mode. Display in updated 4 times each second.

29. Pointers: Displayed to indicate position on bar graph scale.

Positions are updated 20 times each second.

30. Analog Display Polarity: Displays + or - when the pointers

are displayed.

31. 0 to 400A: (or 0 to 800A) numeric reference for the bar gra p h .

32.

: Displayed when internal battery needs replacing.

C o n t rols and Indicators

1. C l a m p : Opens 2.04 inches (52 mm) to enclose conductors.

2. Hold: Freezes reading in digital display.

3. Display: Liquid crystal display.

4. Range: Selects 0 to 40A, 0 to 400A, or AUTO .

5. On Off: Selects meters power ON or power OFF.

6.

: Selects continuity testing mode.

7. Ω: Selects ohms measurement mode.

8. VΩ: Volt, ohms, continuity test input terminal.

9. V: Selects volts measurement mode.

10. COM: Common terminal.

11. Hz: Selects frequency measurement mode.

12. A: Selects aperes measurement mode.

13. MIN/MAX: Selects “REC ORD” mode and displays

recorded MIN / M AX / AV G .

DL235-MAN

P. 2