UEi Test Instruments DCM3 User Manual

Page 3

Advertising
background image

C h a r a c t e r i s t i c s

Specifications

Auto power off:

After meter operation approx. 10 minutes,
auto power off circuit

Test Voltage:

<3.5 V

Input protection:

0.25 A/250 V fast action fuse

Zero adjust limited:

±20 pF approx

Shock proof:

New structure, shock proof from 3 meter drop.

Display:

3 1/2 digit liquid crystal display (LCD) with maximum
reading of 1999

Polarity:

Automatic, positive implied, negative polarity indica t i o n

Over range:

[1] or [-1] is displayed

Zero:

Automatic

Low battery indication:

The " " is displayed when the battery voltage drops
b e l ow the operating level

Measurement rate:

2.5 times per second

Operation environment:

0˚C ~ 60˚C at 70% relative humidity

Storage temperature:

-20˚C ~ 60˚C, 0 to 80% R.H. with battery removed

Accuracy:

Stated accuracy at 23˚C ±5˚C, < 75% relative humidity

Power:

Single standard 9 volt battery (NEDA 1604 pr JIS 006P)

Battery life:

200 hours typical with carbon-zinc

Dimension:

150 mm (H) x 70 mm (W) x 38 mm (D)

Weight:

Approx. 170g including battery

Accessories:

One pair test leads, 9V battery, operating instructions

DCM3-MAN

P. 2

Range

Resolution

Accuracy

Test Frequency

20 0 p F

0.1pF

20 0 0 p F

1pF

20 n F

10pF

20 0 n F

100pF

±1%rdg + 3dgt

820Hz

2 u F

1nF

20 u F

10nF

82Hz

20 0 u F

100nF

20 0 0 u F

1uF

2%rdg + 3dgt

8.2Hz

20 m F

10uF

4%rdg + 9dgt