6.4. Sequential Cooling Flow for USB Connection

Send 200 bytes of Invalid command

Send print data.

Return “NAK” from
cooling.

△

Cooling

The printer is initialized.

Initialize

Printing

Begin printing without
waiting for a print
command.

Receive data.

The status of the Printer
(media, etc.) is checked
and a response is sent.

Status (response status to status information request)

If there are no problems with
the Printer status (media, etc.),
the data is transmitted. If there
is a problem, an error appears.

Send control code.

Status

(Phase change :

“Printing state”)

Sending display

Send print data.

Send print data.

Send print data.

Send print data.

When cooling is finished,
“Notification: Cooling(finish)”
is returned.

0 packet

0 packet

0 packet

0 packet

Continue reading.
0 packets are returned
while cooling.

Send print data.

Status (Notification:”Cooling(finish)”)

failed

Repeat reading of maximum
and transmission timeout
times. If the transmission
timeout is exceeded, perform
a read, and display the
cooling status if a
high-temperature error is
returned.

Send print data.

×

Status

(Notification:

“Cooling(start)”)

Status information request

Computer (host)

Printer

In order to clear any jobs
with errors remaining in
the printer

Perform a READ.

Perform a READ.

Restart

Brother QL-500/550/560/570/580N/650TD/700/1050/1060N Command Reference