TROUBLESHOOTING AND ROUTINE MAINTENANCE 12 - 16

White Spots on black text

and graphics at 3.7 in.

(94 mm) intervals

Black Spots at 3.7 in.

(94 mm) intervals

If the problem is not solved after printing a few pages, the drum unit may
have glue from label stock on the OPC drum surface.

Clean the drum unit as follows:

1 Position the print sample in front of the drum unit, and find the exact

position of the poor print.

2 Turn the drum unit gear by hand while looking at the surface of the

OPC drum.

Do not touch the photosensitive drum with your fingers.

3 When you have located the mark on the drum that matches the print

sample, wipe the surface of the OPC drum with a cotton swab until
the dust or paper powder on the surface comes off.

Do not try to clean the surface of the photosensitive drum with a

sharp object. (e.g. ball-point pen, paper clip etc.)

The drum unit may be damaged. Put in a new drum unit. (See Replacing
the drum unit
on page 12-30.)

Examples of poor print