LV-8320 Basic Serial Command Specifications

-23-

7.8. Temp Read Command

Command “CR6”

[CR]

Detail

Get the temperature data inside the projector.
With some temperature sensors installed in the projector, it is possible to get all
the temperature at once.

Response

Acceptable “%1_%2_%3”

[CR]

%1
%2
%3

%1=Temperature of sensor 1
%2=Temperature of sensor 2
%3=Temperature of sensor 3
Temperature data is shown as “00.0”.
When the temperature goes down to -, the first character
becomes “-” instead of a space, like “-05.5” [CR].
When no temperature data can be returned due to hardware
problems, the first character becomes “E” like”E00.0” [CR].
When several temperature sensors are equipped, Responses are
returned continuously.
“_31.5 _ _35.2 _ _33.4”[CR]
The first data is sensor 1, then one space, and the data of sensor
2 follows.

Unacceptable

“?”[CR]

7.9. Lamp Mode Read Command

Command “CR7”

[CR]

Detail

Get lamp mode status.
For 1 lamp projector, get if it is lighting or not.

Response

Acceptable “%1”

[CR]

%1

“00” [CR]=Light is out.
“01” [CR]=Light is on.

Unacceptable

“?”[CR]