C: Setting Custom Functions

C.Fn-04:

)

(FEB sequence)

You can change the shooting order of the FEB sequence: 0: Standard
exposure, -: Decreased exposure (darker) and +: Increased exposure
(brighter).

0:

0

 +

1:

 0  +

C.Fn-05:

*

(Flash metering mode)

You can change the automatic flash metering mode for flash shooting.

0:

E-TTL II/E-TTL

1:

TTL

C.Fn-06:

+

(Quick flash with continuous shot)

You can set whether or not to fire Quick flash (to perform firing when the
flash-ready lamp lights in green) in continuous shooting.

0:

OFF (Disabled)

1:

ON (Enabled)

When using an EOS DIGITAL camera or EOS REBEL T2/EOS 300X, do not
set to 1. Depending on the camera model, the flash metering may not be
controlled correctly; for example, the flash may not fire, or it may always fire
at full output. Also, wireless multiple flash shooting cannot be performed.

When setting functions from the camera’s menu, [2: Auto external flash
metering
] and [3: Manual external flash metering] may be displayed in
gray. In this case, they cannot be selected.

1 is the setting for shooting with TTL autoflash on Type-A EOS film
cameras or using Type-B EOS film cameras.

When using a Type-B camera, you cannot perform E-TTL II/E-TTL
autoflash shooting even when 0 is set.

When Quick flash (p.18) is fired during continuous shooting, underexposure
may occur since the effective flash range becomes shorter. Setting 1 is
recommended only when you want to shorten the shooting interval.