WARNING!
On some points of the machine there are some adhesive plates indicating:

DANGER

WARNING

CAUTION

CONSULTATION

While reading this Manual, the operator must pay careful attention to the symbols shown on the plates.
Do not cover these plates for any reason and immediately replace them if they are damaged.

BATTERY CHECK/SETTING ON A NEW MACHINE

WARNING!
The electric components of the machine can be seriously damaged if the batteries are either improperly installed
or connected. The batteries must be installed by qualifi ed personnel only. According to the type of batteries
(WET or GEL), set the electronic board of the machine.
Check the batteries for damage before installation.
Disconnect the battery connector and the battery charger plug.
Handle the batteries with great care.
Install the battery terminal protection caps supplied with the machine.

The machine requires one 24 V battery, or four 6 V batteries in serial connection.
The machine can be supplied in one of the following confi gurations:

Batteries already installed and ready to be used

a)

Batteries installed on the machine but without electrolyte

b)

Without batteries

c)

According to machine confi guration, proceed as follows.

Batteries already installed and ready to be used

a)

Open the hood (13) and engage the hood support rod (36).

1.

Check that the batteries are connected to the machine with the connector (25).

2.

Disengage the support rod (36) and close the hood.

3.

Insert the ignition key (67) and turn it to “I”, without pressing the pedal (69).

4.

If the green warning light (63) turns on, the batteries are charged.
If the yellow (62) or red (61) warning light turns on, the batteries must be charged (see the procedure in Maintenance
chapter).