29

* C.Fn-8 and C.Fn-9 apply to the MT-24EX only.

C.Fn-4: If 1 is set and both flash tubes/heads are selected to fire with autoflash,

the modeling flash will be fired by both A and B at the same output. With
manual flash, the modeling flash will be fired according to the flash ratio
that was set.

C.Fn-5: If 1 is set, any slave units whose slave ID has been set to A or B will fire in

the same group as flash tube/head A or B set as the master unit.

C.Fn-6: If 1 is set and you press the camera’s depth-of-field preview button, you

can check the depth of field. The modeling flash cannot be fired.

Custom Function Settings

C.Fn

Function

No.

Setting Description

1

Automatic cancellation
of FEB

0

Enabled

1

Disabled

2

FEB sequence

0

Standard exposure

 Decreased

exposure

 Increased exposure

1

Decreased exposure

 Standard

exposure

 Increased exposure

3

Flash metering mode

0

E-TTL II/E-TTL autoflash

1

TTL autoflash

4

Test firing button

0

E-TTL II/E-TTL autoflash: Full output
Manual flash: Fires at set output

1

Uniform modeling flash

5

Wireless control

0

Slave C only

1

Slaves A, B, and C

6

Modeling Flash

0

Enabled

1

Disabled

7

Flash recycling with
external power source

0

Recycle with both the MR-14EX/MT-
24EX and external power source

1

Recycle with the external power
source only

8

Flash ratio increments

0

1/2 stop

1

Full stop

9

Focusing lamp on/off

0

With focusing lamp button

1

Double-click shutter button

MR14_MT24_02.fm Page 29 Saturday, January 23, 2010 10:46 AM