Asante Technologies GX5-424W User Manual

Page 31

Advertising
background image

Asanté FriendlyNET GX5-424W/448W/2400W

User’s Manual

31

Trap Setting

Traps are messages sent by the switch to a trap receiver. Use the GX5-W Management Utility as
your trap receiver. You can configure the switch to send traps to the trap receiver for several
kinds of events. Select each of the following trap types by clicking its check box.

Trap IP

Enter the IP address of the device to which you would like to send traps.

System Events: monitoring the system’s trap

Device Bootup—a trap will be sent each time the device boots up

Illegal Login—if a login attempt is made with an invalid password, the system will send a trap,
and include the IP address from which the invalid attempt was made

Fiber Port Events: sent for signal faults on the fiber ports

Link Up/Link Down—sent each time a fiber port notes a new link or loses a previously
established link

Abnormal receive error—a trap is sent when more than 50 errors are noted within 10 seconds

Abnormal transmit error—a trap is sent when more than 50 errors are noted within 10
seconds

Copper Port Events: sent for signal faults on the twisted pair ports

Link Up/Link Down—sent each time a fiber port notes a new link or loses a previously
established link

Abnormal receive error—a trap is sent when more than 50 errors are noted within 10 seconds

Abnormal transmit error—a trap is sent when more than 50 errors are noted within 10
seconds