Chapter 7 technical specifications – Asante Technologies GX5-424W User Manual

Page 36

Advertising
background image

Asanté FriendlyNET GX5-424W/448W/2400W

User’s Manual

36

Chapter 7 Technical Specifications

Ports

Fast Ethernet:

24 or 48 x 10/100BaseTX Fast Ethernet ports with Auto-Uplink: RJ-45 shielded
connectors

Gigabit Ethernet:

2 x 10/100/1000BaseT Gigabit Ethernet ports with Auto-Uplink: RJ-45 shielded

connectors
2 x 1000BaseX Gigabit Ethernet ports: SPF Mini-GBIC

Configuration:

IEEE auto-negotiation (sets 10/100/1000 Mbps speed and half/full duplex) or

manual configuration via web management

Expansion:

Uplink using Gigabit Ethernet ports. Selectable trunking for 4000 Mbps aggregate

bandwidth using 1000BaseT ports

Status Indicators

System:

Power

Per 10/100 Port:

Link (solid)/activity (blink) and 100 Mbps

Per 1000 Port:

Link (solid)/activity (blink), 1000 Mbps and 100 Mbps (1000BaseT only)

Performance

Efficiency:

Wire-speed Gigabit Ethernet switch

Switch Fabric:

12.8 Gbps aggregate (GX5-424W)
33.6 Gbps aggregate (GX5-448W)

28 Gbps aggregate (GX5-2400W)

Switch Architecture:

Store-forward and integrated broadcast storm filtering

Flow Control:

IEEE 802.3x flow control (full duplex) and back pressure (half-duplex)

Link Aggregation:

1 trunk/2 ports

Forwarding MAC Table:

4000 addresses with automatic learning and aging

Buffer:

1152 KB total (GX5-424W)
1536 KB total (GX5-448W)
400 KB (GX5-2400W)

Web Management

System Requirements:

Internet Explorer 5, Netscape 6, Apple Safari 1, and later. Windows
98/Me/2000/NT/XP and Mac OS X

Port Settings:

Speed (disable, auto, 10 or 100 Mbps, full or half-duplex), flow control, QoS (normal

or high)

Port-Based VLAN:

Add or delete group, select members

Trunk:

Aggregate 1000BaseT ports into 1 trunk (4000 Mbps bandwidth, full duplex)

Mirror:

Sniffer mode (receive, transmit or both), port and source port(s)

Overview:

Transmit (OK and error) and receive (OK and error),

Port Statistics:

Transmit (bytes, unicast, multicast, broadcast, drop, pause, deferred, late collision,
collision, excessive collision), receive (bytes, unicast, multicast, broadcast,
undersize, jabber, FCS error, drop, pause, excess size, oversize, fragment, SA

change, count by size)

System:

Name, location, timeout, IP address, subnet mask and gateway

Trap Settings:

IP of monitoring station running GX5-W Management utility, system events, SFP

and 1000BaseT port events

Backup:

Save/restore configuration and upgrade firmware

Reset:

Reset to factory defaults and reboot switch

Advertising
This manual is related to the following products: