prepare the wiring as follows:

‡ The screws which fasten the wiring to

the terminal block may come loose from
vibrations during transportation.

‡ Check and make sure all screws are well

¿[HG2WKHUZLVHLWFRXOGFDXVHEXUQRXW
of the wires.

‡ %HVXUHWKHFLUFXLWFDSDFLW\LVVXI¿FLHQW

‡ Ensure the starting voltage is maintained

at over 90% of the rated voltage marked
on the nameplate.

‡ &RQ¿UPWKDWWKHFDEOHWKLFNQHVVLV

DVVSHFL¿HGLQWKHSRZHUVRXUFH
VSHFL¿FDWLRQ

‡ Always install a Residual Current Device

(RCD) in wet or moist area.

‡ The following may be caused by voltage

drop: Vibration of a contactor, which will
damage the contact point, fuse blowing,
disturbance of the normal function of the
overload.

‡ The means for disconnection from a

power supply shall be incorporated in the
¿[HGZLULQJDQGKDYHDQDLUJDSFRQWDFW
separation of at least 3mm in each active
(phase) conductor.

Downward
slope

B. Check the drainage

‡ Carefully pour a glass of water on the

evaporator.

‡ (QVXUHWKHZDWHUÀRZVWKURXJKWKHGUDLQ

hose of the indoor unit without any leakage
DQGJRHVRXWWKHGUDLQH[LW

Drain hose

C. Dain piping

‡ The drain hose should

point downward for
HDV\GUDLQÀRZ

Step 10: Checking the Drainage

A. Open and lift the indoor unit front panel.

‡ Hold the lower part of the left and right sides

of the panel, pull it against you and lift it stops
with a full support from the bracket.

‡ Do not place drain piping as indicated below:

Panel
bracket

caution

Accumulated
drain water

Do not rise

Tip of drain
hose dipped
in water

Air

Space less
than 50mm

Water
leakage

Water
leakage

Water
leakage

Ditch