Alto-Shaam 10.18 User Manual

Page 11

Advertising
background image

ELECTRIC COMBITHERM

INSTALLATION MANUAL

#MN-28677

PG

. 9

®

C O M B I T HE R M

1 0 • 1 0

E S

iN

S P E C I F I C A T I O N S

C A PA C I T Y

FULL-SIZE PANS: 20" x 12" x 2-1/2"

Ten (10)

Eight (8)

GN 1/1: 530 x 325 x 65mm

Ten (10)

Eight (8)

HALF-SIZE SHEET PANS:*

18" x 13" x 1"

Ten (10)

Nine (9)

ON WIRE SHELVES ONLY

120 lb (54 kg)

MAXIMUM

VOLUME MAXIMUM

: 75

QUARTS

(95

LITERS

)

W E I G H T

NET

385 lb

EST

.

(175 kg)

EST

.

SHIP

500 lb

EST

.

(227 kg)

EST

.

CRATE

49"

X

44"

X

40"

EST

.

DIMENSIONS

:

(1245 x 1118 x 1016mm)

E L E C T R I C A L

1 0 • 1 0

E S

i N

1 0 • 1 0

E S

i N / s k

VOLTAGE

PHASE

CYCLE

/

HZ

AWG

AMPS

kW

AMPS

kW

at 208

1*

50/60

2 Wire plus ground

67.0

13.9

69.2

14.4

at 240

AWG 3

77.0

18.4

79.0

18.9

at 208

3

50/60

3 Wire plus ground

38.6/ph

13.9

40.0/ph

14.4

at 240

AWG 6

44.3/ph

18.4

45.5/ph

18.9

at 380

3

50/60

4 Wire plus ground

21.1/ph

13.9

22.0/ph

14.4

at 415

AWG 10

25.6/ph

18.4

26.3/ph

18.9

at 440

3*

50/60

3 Wire plus ground

20.0/ph

15.4

21.0/ph

15.9

at 480

AWG 8

22.0/ph

18.4

23.0/ph

18.9

*

ELECTRICAL SERVICE CHARGE APPLIES

20

8-

24

0

20

8-

24

0

38

0-

41

5

44

0-

48

0

1

9

-1

/2

"

(4

9

5

m

m

)

1

2

-5

/1

6

"

(3

1

2

m

m

)

9

-9

/1

6

"

(2

4

2

m

m

)

35-7/8" (910mm)

33-7/8" (860mm)

33" (837mm)

2" (50mm)

35-11/16" (905mm)

25"

(635mm)

19-9/16"

(496mm)

7-9/16"

(191mm)

5" (126mm)

Water Drain

(Side Back)

Steam

Vent

(Top)

21-15/16"

(557mm)

41-1/16" (1043mm)

4-3/4" (120mm)

2-3/16" (55mm)

Electrical Connection(Bottom)

5

4

-1

/8

"

(1

3

7

5

m

m

)

7

-9

/1

6

"

(1

9

2

m

m

)

3

3

-7

/8

"

(8

5

9

m

m

)

4

1

-3

/8

"

(1

0

5

0

m

m

)

Treated Water

Intake (Bottom)

Untreated Water Intake

(Bottom)

WATER

DRAIN

6

-3

/8

"

(1

6

1

m

m

)

Low Pressure

Valve

D I M E N S I O N S :

H x W x D

EXTERIOR

:

41-3/8" x 35-7/8" x 35-11/16" (1050mm x 910mm x 905mm)

EXTERIOR

WITH

RETRACTABLE

DOOR

:

41-3/8" x 39-7/8" x 35-11/16" (1050mm x 1012mm x 905mm)

INTERIOR

:

27" x 13-1/4" x 26-1/4" (685mm x 387mm x 665mm)

*

ADDITIONAL WIRE SHELVES REQUIRED FOR MAXIMUM CAPACITY

I N S TA L L AT I O N R E Q U I R E M E N T S
Oven must be installed level.

Hood installation is required.

Water supply shut-off valve and back-flow

preventer.

C L E A R A N C E R E Q U I R E M E N T S

LEFT

: 6" (152mm)

PLUS SERVICE ACCESS

:

18" (457mm)

RECOMMENDED

20" (508mm)

F R O M H E AT P R O D U C I N G E Q U I P M E N T

RIGHT

: 4" (102mm)

TOP

: 20" (508mm)

FOR AIR MOVEMENT

BACK

: 4" (102mm)

BOTTOM

: 5-1/8" (130mm)

FOR LEGS

COUNTER

-

TOP INSTALLATIONS MUST MAINTAIN

4" (102mm)

MINIMUM

CLEARANCE FROM COUNTER SURFACE

.

WAT E R R E Q U I R E M E N T S

TWO (2) COLD WATER INLETS - DRINKING QUALITY

ONE

(1)

TREATED WATER INLET

:

3/4" NPT*

ONE

(1)

UNTREATED WATER INLET

:

3/4" NPT*

LINE PRESSURE

:

30 to 90 psi

2.8 to 6.2 bar

WATER DRAIN: 1-1/2"

CONNECTION WITH AIR GAP

* Can manifold off of one 3/4" line.

WAT E R Q U A L I T Y M I N I M U M S TA N D A R D S

USING A WATER SUPPLY NOT MEETING ALTO-SHAAM'S

MINIMUM WATER QUALITY STANDARDS WILL VOID THIS

WARRANTY. It is the responsibility of the purchaser to ensure that

incoming water supply is compliant with the specifications listed

through adequate treatment measures. Installation of the

CombiGuard™ Water Filtration System is recommended, but this

system may not address all water quality issues present.

Contaminant

Inlet Water Requirements

(untreated water)

Free Chlorine

Less than 0.1 ppm (mg/L)

Hardness

Less than 3 gpg (52 ppm)

Chloride

Less than 30 ppm (mg/L)

pH

7.0 to 8.5

Alkalinity

Less than 50 ppm (mg/L)

Silica

Less than 12 ppm (mg/L)

Total Dissolved

Solids (tds)

Less than 60 ppm

Advertising