L O C AT I O N S I T E & I N S TA L L AT I O N R E Q U I R E M E N T S

POSITIONING REQUIREMENTS

In order to ensure proper ventilation, a

minimum distance of at least 6-inches (152mm)

must be kept from the control panels side (left)

of the oven and any adjoining surfaces.

NOTE:

Additional clearance is needed for

service access. A minimum distance of 18-inches

is strongly recommended. If adequate service

clearance is not provided, it will be necessary to

disconnect the gas, water, and drain to move the

oven with a fork lift for service access. Charges

in connection with inadequate service access is

not covered under warranty.

Allow a minimum of 4-inches (102mm) from the

right side of the oven to allow the door to open

to at least a 90° angle. Fully opened, the door

will extend up to a 225° angle If the oven is

furnished with the retractable door option,

allow a minimum clearance of

6-1/2 inches (165mm).

Allow a minimum clearance of 4-inches

(102mm) from the back of the oven for

plumbing connections.

Allow a 20-inch (500mm) clearance at the top of

the oven for free air movement and for the

steam vent(s) located at the top.

Do not install the oven adjacent to heat

producing equipment such as fryers, broilers,

etc. Heat from such appliances may cause

damage to the controls of the Combitherm.

Minimum clearance recommended:

20-inches (500mm)

Place the Combitherm oven on a stable,

non-combustible level horizontal surface. For

countertop models, the oven

stand must be

level. In

addition, the

overall height of the oven should be positioned so

the operating controls and shelves may be

conveniently reached from the front. Level the

oven front-to-back and side-to-side by means of

the adjustable legs.