English, Common problems and solutions – LG LW1810HR User Manual

Page 21

Advertising
background image

Owner’s Manual 21

ENGLISH

Maintenance and Service

Common Problems and Solutions

Before calling for service, please review the following list of common problems and solutions.

The air conditioner is operating normally when:
• You hear a pinging noise. This is caused by water being picked up by the condenser on rainy days or in

highly humid conditions. This feature is designed to help remove moisture in the air and improve cooling
efficiency.

• You hear the thermostat click. This is caused by the compressor cycle starting and stopping.
• You see water dripping from the rear of the unit. Water may be collected in the base pan in highly humid

conditions or on rainy days. This water overflows and drips from the rear of the unit.

• You hear the fan running while the compressor is silent. This is a normal operational feature.

The air conditioner may be operating abnormally when:

Problem

Possible Causes

What To Do

■ The air conditioner is

unplugged or not plugged
in completely

■ The fuse is blown/circuit

breaker is triggered

■ Power failure.

■ The current interrupter

device is tripped.

■ Air flow is restricted

■ TEMP Control set too

higher number.

■ The air filter is dirty.

■ The air conditioner was

just turned on.

■ The room may have been

hot.

■ Cold air is escaping.

■ Cooling coils are iced up
■ The cooling coils are iced

over.

• Make sure the plug is completely plugged into the

outlet

• Check the fuse/circuit breaker box and replace the

fuse or reset the breaker

• In the event of a power failure, set the power control

to OFF. When the power is restored, wait 3 minutes
to restart the air conditioner to prevent the
compressor from overloading

• Press the RESET button located on the power cord

plug. If the RESET button will not stay engaged,
discontinue use of the air conditioner and contact a
qualified service technician.

• Make sure there are no curtains, blinds, furniture or

other obstacles in front of the air conditioner

• Set the TEMP control to a lower number.

• Clean the filter at least every 2 weeks. Refer to the

“Maintenance and Service” section of the manual.

• After the air conditioner is turned on, you need to

give the air conditioner some time to cool the room.

• When the air conditioner is first turned on

you need to allow time for the room to cool down.

• Check for open furnace floor resisters and cold air

returns.

• CLOSE the air conditioner vent

• See Ice appears on the air conditioner below

• Ice may block the air flow and obstruct the air

conditioner from properly cooling the room.

• Set the mode control at HIGH fan or high cool with

the high temperature.

The air conditioner
does not operate
at all

Air conditioner
does not cool

Ice appears on the
air conditioner.

Advertising