Warning, Connecting electric dryers (cont.) usa only – LG DLGY1202V User Manual

Page 25

Advertising
background image

25

ENGLISH

iNSTALLATiON iNSTruCTiONS

Connecting electric dryers (cont.)

USA only

w

WArNiNg

Connect the power cord to the terminal block. Connect each

power cord wire to the terminal block screw that has the

same colored wire. For example, connect the black power

cord wire to the terminal block screw with the black wire.

Failure to follow these instructions may result in a short,

overload, fire or death.

Grounding through the neutral conductor is prohibited

for: (1) new branch-circuit installations, (2) mobile homes,

(3) recreational vehicles, and (4) areas where local codes

prohibit grounding through the neutral conductor.

three-wire connection for electric dryers:

power cord

• A 3-wire connection is NOT permitted on new construction after

January 1, 1996.

• A UL-listed strain relief is required.

1. Remove the terminal block access cover on the upper back of

the dryer. Install a UL-listed strain relief into the power cord
through-hole; then thread a UL-listed, 30 A, 240 V, 3-wire, #10
AWG-minimum copper
conductor power cord through the
strain relief.

• Use a 30 A, 240 V, UL-listed power cord with #10 AWG-

minimum copper conductor and closed loop or forked

terminals with upturned ends.

2. Attach the two hot leads of the power cord to the outer

terminal block screws. Attach the neutral wire to the center

terminal block screw. Connect the external ground (if required

by local codes) to the green ground screw. TIGHTEN ALL

SCREWS SECURELY. Reinstall the terminal block access cover.

UL-Listed

Strain Relief

UL-Listed

3-Wire Power

Cord

Terminal

Block

Ground

Screw

Neutral

(White)

Hot

(Black)

Hot

(Red)

External Ground

Wire (If required

by local codes)

White Wire

from Dryer

harness

Advertising