Electrical Requirements for Gas Models Only

Do not, under any circumstances, cut or

remove the third (ground) prong from the

power cord. Failure to follow this warning can

result in fire, explosion, or death.

For personal safety, this dryer must be

properly grounded. Failure to follow this warning

can result in fire, explosion, or death.

The power cord of this dryer is equipped with

a 3-prong (grounding) plug which mates with

a standard 3-prong (grounding) wall outlet

to minimize the possibility of electric shock

hazard from this appliance. Failure to follow

this warning can result in fire, explosion,

or death.

This dryer must be plugged into a

120-VAC, 60-Hz. grounded outlet protected by

a 15-ampere fuse or circuit breaker. Failure to

follow this warning can result in fire, explosion, or

death.

Where a standard 2-prong wall outlet is

encountered, it is your personal responsibility

and obligation to have it replaced with a

properly grounded 3-prong wall outlet. Failure

to follow this warning can result in fire, explosion,

or death.

16

CONNECTING GAS DRYERS

Gas supply requirements:

As shipped from the factory, this dryer

is configured for use with natural gas.

It can be converted for use with LP (Liquefied

Propane) gas. Gas pressure

must not exceed 13 in. water column.

A qualified service or gas company technician

must connect the dryer to the gas service.

Failure to do so can result in fire, explosion, or

death.

Isolate the dryer from the gas supply system

by closing its individual manual shutoff valve

during any pressure testing of the gas supply.

Failure to do so can result in fire, explosion, or

death.

Supplylinerequirements:

Your laundry room must have a rigid gas

supplylinetoyourdryer.IntheUnitedStates,

anindividualmanualshutoffvalveMUSTbe

installed within at least 6 ft. (1.8 m) of the

dryer, in accordance with the National Fuel

GasCodeANSIZ223.1.A1/8-in.NPTpipe

plug must be installed. Failure to do so can

result in fire, explosion, or death.

If using a rigid pipe, the rigid pipe should be

1/2-in.IPS.Ifacceptableunderlocalcodes

and ordinances and when acceptable to your

gas supplier, 3/8-in. approved tubing may be

used where lengths are less than 20 ft. (6.1

m). Larger tubing should be used for lengths

in excess of 20 ft. (6.1 m). Failure to do so can

result in fire, explosion, or death.

Connect the dryer to the type of gas shown

on the nameplate. Failure to do so can result in

fire, explosion, or death.

To prevent contamination of the gas valve,

purge the gas supply of air and sediment

before connecting the gas supply to the dryer.

Before tightening the connection between the

gas supply and the dryer, purge remaining air

until the odor of gas is detected. Failure to do

so can result in fire, explosion, or death.

DO NOT use an open flame to inspect for

gas leaks. Use a noncorrosive leak-detection

fluid. Failure to do so can result in fire, explosion,

or death.

UseonlyanewAGA-orCSA-certifiedgas

supply line with flexible stainless steel

connectors. Failure to do so can result in fire,

explosion, or death.

Securelytightenallgasconnections. Failure to

do so can result in fire, explosion, or death.

Use Teflon

®

tape or a pipe-joint compound

that is insoluble in Liquefied Petroleum (LP)

gas on all pipe threads. Failure to do so can

result in fire, explosion, or death.

DO NOT attempt any disassembly of the

dryer; any disassembly requires the attention

and tools of an authorized and qualified

service person or company. Failure to do so

can result in fire, explosion, or death.

w

WARNING:

To reduce the risk of fire, electric shock, or injury to persons when using this

appliance, follow basic precautions, including the following: