CONNECTING ELECTRIC DRYERS

(cont.)

Remove 3

1

2

inches (8.9 cm) of the outer

covering from the wire. Strip 1 inch (2.5 cm)

insulation from each wire. Bend the ends of

the three wires into a hook shape.

1

Attach the two hot leads of the power cord

to the outer terminal block screws. Attach

the neutral wire to the center terminal block

screw. Connect the external ground (if

required by local codes) to the green ground

screw. TIGHTEN ALL SCREWS SECURELY.

Reinstall the terminal block access cover.

3

Ground Screw

Neutral

(White)

Hot

(Black)

Ground Wire

Hot

(Red)

Remove the terminal block access cover

on the upper back of the dryer. Install a

UL-listed strain relief into the power cord

through-hole; then thread the power cable

prepared in Step 1 through the strain relief.

2

UL-Listed

Strain Relief

UL-Listed

3-Wire

Power Cord

Terminal

Block

1" (2.5 cm)

Three-Wire Connection for Electric Dryers: Direct Wire

• A 3-wire connection is NOT permitted on new

construction after January 1, 1996.

• A UL-listed strain relief is required.

• Use UL-listed 3-wire #10 AWG-minimum copper

conductor cable.

• Allow at least 5 ft (1.5 m) length to allow for

removal and reinstallation of the dryer.

w

WARNING:

•Connectthepowercordtotheterminalblock.Eachcoloredwireshouldbeconnectedto

same color screw. Wire color indicated on manual is connected to the same color screw

in block. Failure to follow these instructions may result in a short or overload.

•Groundingthroughtheneutralconductorisprohibitedfor:(1)newbranch-circuit

installations, (2) mobile homes, (3) recreational vehicles, and (4) areas where local

codes prohibit grounding through the neutral conductor.