How to install the unit window requirements, Preparation of chassis, Notice – LG LW1213HR User Manual

Page 12

Advertising
background image

How to Install the Unit

Window Requirements

1. To prevent vibration and noise, make sure the unit

is installed securely and firmly

2. Install the unit where the sunlight does not shine

directly on the unit.

3. The outside of the cabinet must extend outward for

at least 12" and there should be no obstacles, such

as a fence or wall, within 20" from the back of the

cabinet because it will prevent heat radiation of the

condenser.

Restriction of outside air will greatly reduce the

cooling efficiency of the air conditioner.

All side louvers of the cabinet must remain exposed to the outside of the structure.

4. Install the unit slightly tilted so the back is slightly lower than the front (about

1

/

2

").

This will force condensed water to flow to the outside.

5. Install the unit with the bottom between 30"~60" above the floor level.

All supporting parts should be secured to firm wood,
masonry, or metal.

This unit is designed for installation in standard
double hung windows with actual opening widths
from 27" to 39".
The top and bottom window sash must open
sufficiently to allow a clear vertical opening of
16" from the bottom of the upper sash to the window stool.

NOTICE

About

1

/

2

"

30"~60"

Awning

Cooled air

Fence

Over 20"

Heat

radiation

12

Shipping

Screws

27

39

16

Preparation Of Chassis

(Keep the screws for later use.)

Remove 4 screws which fasten the cabinet at both

sides and at the back.

Advertising