background image

22 Multi Type Air Conditioner

Maintenance and Service

CAUTION: Before performing any maintenance, turn off the main power to the system.

Grille, Case, and Remote Control

o Turn the system off before cleaning.

To clean, wipe with a soft, dry cloth. Do not use
bleach or abrasives.

Supply power must be disconnected

before cleaning the indoor unit.

AIR FILTERS

The air filters behind the front grille should be
checked and cleaned once in every 2 weeks or
more often if neccessary.

PLASMA FILTER, TRIPLE
DEODORIZING FILTER(OPTIONAL)

The PLASMA filter behind the air filters should be
checked and cleaned once in every 3 months or
more often if necessary.

o Never use any of the followings:

Water hotter than 40°C

Could cause deformation and/or
discoloration.

Volatile substances

Could damage the surfaces of the air
conditioner.

1. Lift the front access panel and pull the filter tab

slightly forward to remove the filter.

2. Clean the filter with a vacuum cleaner or warm,

soapy water.

• If dirt is conspicuous, wash with a solution

of detergent in lukewarm water.

• If hot water (40°C or more) is used, it may

be deformed.

3. After washing with water, dry well in the shade.

4. Re-install the air filter.

NOTICE

Vertical louver Horizontal louver

Air filters

(behind front panel)

Air outlet vent

Air inlet vent

Gasoline

Powder

TRIPLE DEODORIZING Filter

PLASMA Filter

1. After removing the air filters, pull slightly forward

to remove the PLASMA filter.

2. Remove dust with vacuum cleaner or air.

(You should not try to wash with water).

3. Note the cuts of electric discharge lines.

4. Re-install the PLASMA filter to the original

position.

1. After removing the air filters, pull slightly forward

to remove the TRIPLE DEODORIZING filter.

2. Dry in the sunlight for two hours.

3. Re-install the TRIPLE DEODORIZING filter to

the original position.

Donʼt touch this PLASMA Filter within 10
seconds after opening the inlet grille, it may
cause an electric shock.

Maintenance and Service