background image

Chapter 6: Modulation and Envelopes

A

NDROMEDA

A6 R

EFERENCE

M

ANUAL

157

In

EXAMPLEs 5

,

6

and

7

, the envelope looks at the LFO for absolute values: positive or

negative attributes are ignored – just the level of 75 is used.

EXAMPLE 5

User Parameters:

Trigger In Level =

75

Trigger Polarity =

ABS
BIPOLAR

EXAMPLE 6

User Parameters:

Trigger In Level =

75

Trigger Polarity =

ABS
POSITIVE

EXAMPLE 7

User Parameters:

Trigger In Level =

75

Trigger Polarity =

ABS
NEGATIVE

RETRIG Page
The parameters of the

RETRIG

page are identical to those of the

TRIG

page.

RETRIG

,

however, adds an additional parameter called

STAGE

.

When re-triggering an envelope, you have the added ability to determine at what
stage in the envelope’s cycle where re-triggering takes place. By contrast, the first
trigger that an envelope receives (

TRIG

parameters) always starts at the

DELAY

stage.

You use soft knob

5

to select the desired stage. When re-triggered, the envelope will

start at the beginning of the selected stage:

DEL

DELAY

stage

ATK

ATTACK

stage

D1

D1TIME

(

DECAY 1

) stage

D2

D2TIME

(

DECAY 2

) stage

SUS

SUSTAIN

level; note that sustain will be by-passed if the key or sustain

pedal is not down.

R1

R1TIME

(

RELEASE

1) stage