Rack power subsystem input voltage problem – HP ProLiant BL465c Server Blade User Manual

Page 56

Advertising
background image

NT Event lists for HP BladeSystem Enclosure Monitor Service 56

NT Event Message:
Rack Power Subsystem Not Redundant.
This trap signifies that the rack power subsystem is no longer in a redundant state.
User Action: Replace any failed power supplies as soon as possible to return the system to a redundant

state.
Source IP Address: '%1';
Source Name: '%2';
Rack Name: '%4';
Rack Unique ID: '%5';
Enclosure Name '%6';
Enclosure Serial Number '%7';
Trap Sequence Number '%8'

[SNMP TRAP: 22018 in CPQRACK.MIB]

<a href="https://%1/">Onboard Administrator Web Console</a>

Rack power subsystem input voltage problem

NT Provider: Blade Enclosure
NT Event ID: 22019
NT Event Type: Warning
NT Event Message:
Rack Power Subsystem Input Voltage Problem.
This trap signifies that the rack power supply detected an input line voltage problem.
User Action: Check the power input for the power supply or replace any failed power supplies as soon as

possible.
Source IP Address: '%1';
Source Name: '%2';
Rack Name: '%4';
Rack Unique ID: '%5';
Enclosure Name '%6';
Power Supply Position '%7';
Power Supply Firmware Revision '%8';
Power Supply Input Line Status '%9'
(Power Supply Input Line Status values: 1=no error, 2=over voltage, 3=under voltage, 4=line hit,

5=brown out, 6=line power loss);
Power Supply Spare Part Number '%10';
Enclosure Serial Number '%11';

Advertising