Specifications C-9

Fiber Cable Specifications

To connect to the network, the NC3133, NC6132, and NC6133 upgrade modules use
100 BASE-FX, 1000 BASE-SX, or 1000BASE-LX fiber cable specifications, respectively.

Table C-13

and Table C-14 describe the fiber types, mode, cable size, and maximum distance

specifications for the fiber upgrade modules.

NOTE: All fiber upgrade modules use SC type connectors.

Table C-13

Fiber Cable Maximum Distances for 1000BASE-SX, 1000BASE-LX

(NC6132 and NC6133)

Fiber Type

Mode

Size

Max Distance

1000BASE-SX Multimode 62.5/125

µm

220 meters

Multimode

50/125

µm

550 meters

1000BASE- LX

Multimode

62.5/125

µm

550 meters

Multimode

50/125

µm

550 meters

Single-mode

10

µm

5000 meters

Table C-14

Fiber Cable Maximum Distances for 100BASE-FX (NC3133)

Single Link Between Switches

Mode

Max Distance

FX

Multimode

2000 meters

FX

Multimode

25 km