Y1-06-0209G

13

SECTION 7

– INSTALLING THE HRU IN AN OPEN

FACED BRACKET



The ACR open faced bracket is a
discontinued product that looks like this:









Contents of the HydroFix™ HRU Kit that you will need:

HydroFix

™ Replacement

Hydrostatic Release unit (E)

Open faced release rod (C)

2 Mounting bracket adapters (J)

Mounting rod adapter, metal (L)

Small cotter pin (G)

4 Mounting bracket screws (F)

HRU Expiration Label (K)

Slotted spring pin (I)

Tools required: Phillips-head screwdriver,
pliers

Instructions:
1.) Unscrew the four side screws removing the front cover from the

bottom mounting plate, keeping the screws.

2.) Unscrew the spring loaded HRU Rod from the bracket and remove

the expired HRU. Discard all HRU rods and components.

3.) Align mounting bracket adapters (J) with the screw holes on the

bottom mounting plate (see Figure A).

4.) Using the 4 screws removed from the front cover; loosely attach

mounting bracket adapters (J) to the bottom mounting plate. Some
adjustments may be needed to align the bracket screw holes with

the screw holes on the bottom mounting plate.

5.) Mark the expiry date on the HRU according to the instructions in

Section 3.