SECTION 8

– INSTALLING THE HRU IN A CAPSULE

BRACKET



The ACR capsule bracket is a
discontinued product that looks like this:









Contents of the HydroFix™ HRU Kit that you will need:

HydroFix

™ Replacement

Hydrostatic Release Unit (E)

Capsule design release rod (B)

Keyed bracket adapter (D)

Large cotter pin (H)

HRU expiration label (K)




Instructions:
1.) Remove the front cover and carefully release

the EPIRB from the bracket.

2.) Remove the old HRU unit and rod from the

bracket by pressing the spring release back
and sliding the old HRU up and out of the

bracket.

3.) Take the capsule design release rod (B) and

place on top of the small rod on the HRU
aligning the two sets of holes on the base. (see
Figure A).

4.) Place large cotter pin (H) through the two

holes, securing the two rods together.

5.) Place keyed bracket adapter (D) on the bottom of the HRU. This

part is keyed so that it will fit together only one way. Turn to the right
until it snaps into place.

6.) Mark the expiry date on the HRU according to the instructions in

Section 3.