Di primary – KAL EQUIP KAL 3840 User Manual

Page 14

Advertising
background image

CONTINUTY

OHM

OPEN

CLOSE

IGNITION DI SECONDARY

VEHICLE WFM CYLINDER

BACK RUN

DATA ERASE

PARADE

Function Key Labels

Function keys

Figure 8. Function Key Labels for SECONDARY IGNITION

Figure 8. Single and Dual Input scope in COMPONENT TESTS

BACK SELECT

HELP MENU

PIN # / WIRE COLOR

TEST PROCEDURE

REFERENCE WAVEFORM

THEORY OF OPERATION

TROUBLESHOOTING TIPS

FUNCTION INFORMATION

HELP ( )

DI Primary

Page 1 of 2

Function Info

VEHICLE CYLINDER

FAST KEYS

DATA UPDATE

Giv es a l ist of o ptio ns to d efin e
the type of vehicle under test.

S IN GLE -d i sp l a ys th e i g ni ti o n
pattern of one single cylinder.

P AR AD E-d i sp la ys th e ig n iti o n
p atte rn of al l cyl in de rs in fi rin g
order.

PAGE

BACK

DOWN

VEHICLE

DATA

DI Primary

Page 2 of 2

Function Info

VEHICLE CYLINDER

FAST KEYS

DATA UPDATE

Turns all readings off to make the
me a sur em en t fa ste r an d m ore
reliable.

You can adjust trigger level for a
stab le d isp la y b y u sin g the fou r
way arrow keys.

PAGE

BACK

UP

SINGLE

TRIG LVL

FAST

UPDATE

CYLINDER

SINGLE

PARADE

SINGLE

TRIG LVL

KEYS

TRIG LVL

Figure 7. Information About the Function keys

4-13

Getting Reference Information for the Selected Test

Reference information is available at any time by pressing the HELP key.
Press when finished viewing each area under the HELP menu.

Getting Information About the Function Keys During a Running Test

HELP ( ) When you press this key during a running test, you get information about the function keys that can

be used for the test.

For example,

4-12

CYLINDER

PARADE

SINGLE

Screen Displays

Use Dual Input Scope mode if you want to simultaneously measure t wo wavef orms - one on INPUT A and the other
on INPUT B.

Use SINGLE INPUT SCOPE mode if you want to measure a single signal, INPUT B is turned off.

Use DUAL INPUT SCOPE mode if you want to simultaneously measure two signals.

Using the Function keys

For each test, one or more Function Key Labels are displayed, depending on the sub-selections possible. The
Labels indicate what the keys do when you press them. (See the following example.)

Pressing a function key that has no label has no effect.
The same Function Key Label can appear in several tests and it performs a similar function.

Examples of Function Key Labels

Two separate functions can be allowed to the same function key.
You can use the function key to toggle between the functions.
When you press , you can select between PARADE and SINGLE cylinder test.

When you press , OHM becomes the active function. When
you press , Diode ( ) becomes the active function. When
you press , OPEN CONTINUITY becomes the active function.
Pressing , CLOSE CONTINUITY becomes the active function.

Advertising