Continuity Test

Diode Test

Temperature Measurement

DC Ampere Measurement (Current Probe Output)

AC Ampere Measurement (Current Probe Output)

8-5

(AC+DC) Voltage Measurement

RPM Measurement

Frequency Measurement

Ohm Measurement

8-4

Mode

4 cylinder

2 cylinder

Range

120 - 20000 RPM

60 - 10000 RPM

Accuracy

2 RPM

Range

DC 500 mV

DC 5 V

DC 50 V

DC 500 V

DC 600 V

Resolution

0.1 mV

0.001 V

0.01 V

0.1 V

1 V

40 Hz ~ 400 Hz

± (0.8 % + 5 d)

400 Hz ~ 10 kHz

± (3.0 % + 5 d)

Accuracy

Function

Frequency

% Duty

Dwell

Pulse Width

Range

10 Hz

100 Hz

1 kHz

10 kHz

100 kHz

1 MHz

5 MHz

2.0 % ~ 98 %

3.6 ° ~ 356.4 °

Resolution

0.001 Hz

0.01 Hz

0.1 Hz

1 Hz

10 Hz

100 Hz

1 kHz

0.1 %

0.1 °

Accuracy

± (0.1 % + 3 d)

Pulse Width > 2 µs

1.2 °/krpm + 2 d

2 µs ~ 450 ms (Pulse Width > 2 µs)

Range

500

5 k

50 k

500 k

5 M

30 M

Resolution

0.1

0.001 k

0.01 k

0.1 k

0.001 M

0.01 M

Accuracy

± (0.5 % + 5 d)

± (0.75 % + 5 d)

± (0.75 % + 10 d)

Test Voltage

1.2 V

Threshold

Approx. 70

W

Response time

1 ms

Range

2.0 V

Open Circuit Voltage

3.0 V

Accuracy

± (2.0 %5 d)

Range

-50 °C to 1300 °C

-58 °F to 2372 °F

Resolution

0.1 °C

0.1 °F

Accuracy

± 3 °C

± 5.4 °F

Range

30 mA ~ 20 A

100 mA ~ 40 A

40 A ~ 60 A

Resolution

1 mV/10 mA

1 mV/100 mA

1 mV/100 mA

Accuracy

± (1.5 % + 20 mA)

± (2.0 % + 20 mA)

± (4.0 % + 0.3 A)

Range

30 mA ~ 10 A

100 mA ~ 40 A

40 A ~ 60 A

Resolution

1 mV/10 mA

1 mV/100 mA

1 mV/100 mA

40 Hz ~ 1 kHz

± (2.0 % + 20 mA)

± (2.0 % + 20 mA)

1 kHz ~ 5 kHz

± (4.0 % + 30 mA)

± (6.0 % + 30 mA)

Accuracy

± (8.0 % + 0.3 A)