System parameter for external disk arrays, Thunder 9500v series subsystem – HP StorageWorks XP Remote Web Console Software User Manual

Page 78

Advertising
background image

78

External Storage XP for the XP10000/XP12000

System parameter for external disk arrays

Thunder 9500V Series subsystem

Table 10

explains whether to specify system parameters when making settings on ports on the Thunder

9500V Series subsystem.

The Discovery operation

cannot be performed.

Correct the error and retry the operation.
The source of the error could be one of the following:

Command View XP or XP Remote Web Console is not in Modify mode.

The local disk array port and external disk array port are not connected using

FC cables.

Port security is improperly set on the external disk array.

The status of the device in the external disk array is not Normal.

The external disk array is not connected to a local disk array port set to

External.

The external LUN of the local disk array does not have a status of Normal.

The external LU capacity is insufficient (less than 46.86 MB).

The cable to the switch is not properly connected.

The zoning for the switch is not set properly.

If none of these correct the problem, disconnect and then reconnect the cable

between the local disk array and external disk array. After 30 seconds, retry the

operation.

The external LU is blockaded. Correct the error and retry the operation.

The source of the error could be any one of the following:

All set paths are blockaded (or not connected).

The attribute of the external LU is not set to Read/Write.

The external LU is blockaded by an error.

Table 9

General External Storage XP troubleshooting (continued)

Error

Corrective action

Table 10

System parameter settings (Thunder 9500V Series subsystem)

Pane name

Parameter

Parameter setting

System Startup Settings

Start Attribute

Single Mode

Specify this parameter when the Thunder

9500V Series subsystem is in the

one-controller configuration.

Dual Active Mode

Specify this parameter when the Thunder

9500V Series subsystem is in the

two-controller configuration.

NOTE:

Be sure to specify that Data

Share Mode will be used.

Hot Stand-By Mode

Do not specify this parameter.

Common 1

Delay Planned Shutdown

You can either specify this parameter or

omit specifying this parameter.

OPTION 1

SCSI Fibre Channel Common Options

You can either specify this parameter or

omit specifying this parameter.

OPTION 2

SCSI Fibre Channel Common Options

You can either specify this parameter or

omit specifying this parameter.

Advertising