5.6 SET Command



SET | S [ ALERTS ON|OFF ]
[ CRIT <percent-busy> ]
[ WARN <percent-busy> ]
[ INFO <percent-busy> ]

[ BUSY | % <percent-busy> ]
[ BUSYCPU <percent-busy> ]
[ BUSYPB <percent-busy> ]

[ ENTRIES <number> ]
[ LOGGING ON|OFF ]
[ LOGFILE <filename> ]
[ OBEYESCAPE ON|OFF ]
[ SORT ByCpu | ByNode ]
[ TRACETOKEN ON|OFF ]
[ USECS ON|OFF ]
[ RATE <default-seconds> ]
[ TERM TTY | VT100 | T6530 ]

The S or SET command controls properties of the run-time environment.

ALERTS ON|OFF - reserved for future use.

CRIT <percent> value of Cpu Busy threshold for Critical alerts.
WARN <percent> value of Cpu Busy threshold for Warning alerts.
INFO <percent> value of Cpu Busy threshold for Info alerts.

BUSY | % | BUSYCPU | BUSYPB <percent> indicates the default busy threshold value.
If BUSY|% <percent> is specified then <percent> applies to both the CPU and PB
command. Specifying separate BUSYCPU <percent> or BUSYPB <percent> defines the
BUSY value for the CPU and/or PB commands respectively.

ENTRIES <number> controls the default value of the ENTRIES option for the PB
command.

ObeyEscape ON|OFF controls behavior of interactive commands encountered in an
OBEY file. ON implies interactive commands such as CPU and PB will 'escape' from the