Eva3000 storage system connections, Eva5000 configuration – HP 3000 Enterprise Virtual Array User Manual
Page 26

Browser
Host X
FCA
Management
Server
Command
View EVA
CXO7947B
Controller
A
FCA
FCA
FCA
Host Z
Browser
Non-Host
FP1
FP2
Loop
Pair 1
Loop
Pair 1
Loop
Pair 2
Loop
Pair 2
Controller
B
FP1
FP2
Network Interconnection
FC Loop Switches
FC Loop Switches
Drive Enclosures
Fabric 2
Fabric 1
FP = Fibre (Host) Port
FCA = Fibre Channel Adapter
Cache
Mirror Port
A
A
B
B
Figure 2 EVA5000 configuration
EVA3000 storage system connections
shows a typical EVA3000 SAN topology:
•
The HSV100 controllers connect via two host ports (FP1 and FP2) to the Fibre Channel fabrics.
The hosts that will access the storage system are connected to the same fabrics.
•
The HP Command View EVA management server also connects to the fabric.
•
The controllers connect through one loop pair to the drive enclosures. The loop pair consists
of two independent loops, each capable of managing all the disks should one loop fail. The
controllers connect directly to the disk enclosures.
26
Enterprise Virtual Array startup