Table 6-14 elements of a path – HP Hitachi Dynamic Link Manager Software User Manual

Page 238

Advertising
background image

Displayed Item

Description

No

summary

displayed

Summary

displayed

One of the following values is displayed for each path:

-
Indicates that intermittent error monitoring is disabled or

the monitoring time for an intermittent error is out of

range (the path status is Online(E), Offline(C) or
Offline(E)).

A value of at least 0
Indicates the number of errors that occurred during

intermittent error monitoring (the path status is
Online(E), Offline(E), or Online).

*

Indicates that an intermittent error occurred (automatic

failbacks do not check the path) (the path status is Online,
Online(E), or Offline(E)).

HBAPortWW
N

#1

-

A 16-digit hexadecimal number indicating the WWN

information for an HBA connected to the storage system. This

item is displayed only when you specify the -hbaportwwn

parameter or when you specify hbaportwwn for the -item

parameter.
Note that a hyphen (-) is displayed in the following cases:

When using the EMC DMX, EMC CX, or HP EVA series

When using iSCSI interfaces

Legend:

- : Not displayed

#1

The path information is displayed only when a value is specified for the -
path -item parameter.

#2

In a cluster configuration, an offline operation requested during reserve

processing is put into the waiting-to-execute state, and does not execute

until the reserve processing finishes.

#3

The drive letter assigned to a dynamic disk volume is not displayed.

Table 6-14 Elements of a Path Name

Element

Windows representation

Host port number (hexadecimal)

(example: 0004, 0005)

SCSI port number

Bus number (example: 0001)

SCSI bus number

6-50

Command Reference

Hitachi Dynamic Link Manager User Guide (for Windows(R))

Advertising
This manual is related to the following products: