HP P2000 G3 SAS MSA System User Guide

35

DC model

Locate the two DC power cables provided with your controller enclosure.

Figure 13

DC Power cable featuring sectioned D-shell and lug connectors

See

Figure 13

and the illustration at left (in

Figure 12

) when performing the following steps:

1.

Verify that the enclosure’s power switches are in the Off position.

2.

Connect a DC power cable to each DC power supply using the D-shell connector.

Use the UP> arrow on the connector shell to ensure proper positioning (see adjacent

left side view of D-shell connector).

3.

Tighten the screws at the top and bottom of the shell, applying a torque between 1.7

N-m (15 in-lb) and 2.3 N-m (20 in-lb), to securely attach the cable to the DC power

supply module.

4.

To complete the DC connection, secure the other end of each cable wire component

of the DC power cable to the target DC power source.
Check the three individual DC cable wire labels before connecting each cable wire lug to its power

source. One cable wire is labeled ground (GND) and the other two wires are labeled positive (+L) and

negative (-L), respectively (shown in

Figure 13

above).

CAUTION:

Connecting to a DC power source outside the designated -48V DC nominal range

(-36V DC to -72V DC) may damage the enclosure.

Power cycle

To power on the system:

1.

Power up drive enclosure(s).
Press the power switches at the back of each drive enclosure to the On position. Allow several seconds

for the disks to spin up.

2.

Power up the controller enclosure next.
Press the power switches at the back of the controller enclosure to the On position. Allow several

seconds for the disks to spin up.

To power off the system:

1.

Stop all I/O from hosts to the system.

2.

Shut down both controllers using either method described below:
• Use SMU to shut down both controllers, as described in the online help and HP P2000 G3 MSA

System SMU Reference Guide.
Proceed to

step 3

.

• Use the command-line interface (CLI) to shut down both controllers, as described in the HP

P2000 G3 MSA System CLI Reference Guide.

3.

Press the power switches at the back of the controller enclosure to the Off position.

4.

Press the power switches at the back of each drive enclosure to the Off position.