Power supply leds – HP P2000 G3 MSA Array Systems User Manual

Page 63

Advertising
background image

HP P2000 G3 SAS MSA System User Guide

63

Power supply LEDs

Power redundancy is achieved through two independent load-sharing power supplies. In the event of a

power supply failure, or the failure of the power source, the storage system can operate continuously on a

single power supply. Greater redundancy can be achieved by connecting the power supplies to separate

circuits. DC power supplies are equipped with a power switch. AC power supplies may or may not have a

power switch (model shown below has no power switch). Whether a power supply has a power switch is

significant to powering on/off.

NOTE:

See

Powering on/powering off

on page 33 for information on power-cycling enclosures.

AC model

DC model

Table 18

LEDs — HP P2000 G3 MSA System power supply units — rear panel

LED

Description

Definition

1

Input Source Power Good

Green — Power is on and input voltage is normal.

Off — Power is off or input voltage is below the minimum

threshold.

2

Voltage/Fan Fault/Service Required

Amber — Output voltage is out of range or a fan is operating

below the minimum required RPM.
Off — Output voltage is normal.

1

2

1

2

Advertising