The appliance must be installed by a qualified service

technician. The oven must be properly grounded in

accordance with the National Electrical Code and

applicable local codes.
Plug the unit into a properly grounded receptacle

ONLY, positioning the unit so that the plug is easily

accessible in case of an emergency. Arcing will occur

when connecting or disconnecting the unit unless all

controls are in the “

off

” position.

Proper receptacle or outlet configuration or

permanent wiring for this unit must be installed by

a licensed electrician in accordance with applicable

local electrical codes.
750- and 1000-TH-II models at 208-240V are dual

rated units with a conversion switch mounted under

an access cover on the rear of the oven, near the

power cord.
With the voltage conversion switch in the 200-208V

(UPPER) position, the oven will function properly

with a source voltage of between 200 and 208.
With the voltage conversion switch in the 220-240V

(LOWER) position, the unit will function properly

with a source voltage of between 220 and 240.
NOTE:

ALL 208-240V units are shipped from the

factory with the voltage conversion switch in

the 220-240 position.

All 125V rated units will function properly with a

source voltage of between 100 and 125, 60 Hz.
The 125V rated units are provided with a cord and

plug [NEMA #5-20P]. Have a licensed electrician

install the proper outlet configuration as required

for the unit in accordance with applicable, local

electrical codes. This will assure a safe and trouble-

free installation.

E L E c T r I c A L c O N N E c T I O N

I N S T A L L A T I O N

d A N G E r

To avoid electrical shock, this
appliance MUST be adequately
grounded in accordance with local
electrical codes or, in the absence of
local codes, with the current edition
of the National Electrical Code ANSI/
NFPA No. 70. In Canada, all electrical
connections are to be made in
accordance with CSA C22.1, Canadian
Electrical Code Part 1 or local codes.

ELEcTrIcAL - 1000-TH-II

voltage

phase

cycle

/

hz

amps

kW

cord

&

plug

120

1

60

16.0

1.9

nema

5-20

p

20a - 125v

plug

208-240

(

agcy

)

1

60

14.4

3.0

no

cord

at 208

1

60

14.4

3.0

or

plug

at 240

1

60

11.1

2.7

230

1

50

10.4

2.4

cee

7/7

220-230v

plug

ELEcTrIcAL - 500-TH-II

voltage

phase

cycle

/

hz

amps

kW

cord

&

plug

120

1

60

16

1.9

nema

5-20

p

20a - 125v

plug

208-240

(

agcy

)

1

60

12.5 3.0

no

cord

at 208

1

60

10.6

2.2

or

plug

at 240

1

60

12.2

2.9

230 1 50 12 2.8

cee

7/7

220-230v

plug

ELEcTrIcAL - 750-TH-II

voltage

phase

cycle

/

hz

amps

kW

cord

&

plug

120

1

60

14.2

1.7

nema

5-20

p

20a - 125v

plug

208-240

(

agcy

)

1

60

14.4

3.0

no

cord

at 208

1

60

14.6

3.0

or

plug

at 240

1

60

11.2

2.7

230

1

50

10.4

2.4

cee

7/7

220-230v

plug

Wire diagrams are located inside the bonnet of the unit .

NOTE

:

CE approved appliances must be

connected to an electrical circuit that is

protected by an external GFCI outlet.

Hard wired models:
Hard wired models must be equipped with a

country certified external allpole disconnection

switch with sufficient contact separation.
If a power cord is used for the connection of the

product an oil resistant cord like H05RN or H07RN

or equivalent must be used.

For CE approved units: To prevent an electrical

shock hazard between the appliance and other

appliances or metal parts in close vicinity, an

equalization-bonding stud is provided. An

equalization bonding lead must be connected to

this stud and the other appliances / metal parts

to provide sufficient protection against potential

difference. The terminal is marked

with the following symbol.