Chapter Five - SCSI Bridge Electronics

Tandem 5142-xSE Rackmount Tape Subsystems User Guide

1 9

5.7

Performance LCD Format

Upon receiving a

TEST UNIT READY

or

INQUIRY SCSI

command from the host, the LCD

switches to the Performance Format. This is the main operational format of the LCD. The top two lines
of the LCD always display the current SCSI command and the tape-capacity bar graph. The bottom two
lines of the display alternate between five performance/status items.

C1537A
Rev L610
5170
T133BID5

Write
E F
TOTL XFR
4280MB

Write
E F
XFR RATE

924KB/s

Write
E F
COMPRESS
2.3:1

Write
E F
RWr Rate

0.1%

Write
E F
REMAIN'G

4.4GB

Figure 17

Subsystem's performance LCD format

5.7.1

Current Tape Operation

The current SCSI command being executed displays on the top line of the LCD. Typical
commands shown are

Read, Write, WrtFMK, Rewind, Space,

etc…. (See

Appendix for a complete list of SCSI commands.)

Write
E F

TOTL XFR
74MB

Figure 18

Current tape operation display

Additionally, off-line utilities use this area to display tape-drive errors. The SCSI

Request

Sense

command provides information about an error. Interpretation for bytes 2, 12 and 13 of

Request Sense data may be found in your tape drive manual. For example, the following cyclic
display indicates that an attempted write to a write-protected tape caused the failure.

E R R O R
K E Y = 4 7
A S C = 2 7
S C Q = 0 0