Mirrored memory configuration, Installing fbdimms – HP ProLiant BL480c Server-Blade User Manual

Page 35

Advertising
background image

Hardware options installation 35

After installing FBDIMMs, use RBSU to configure the system for online spare memory support

("

Configuring online spare memory

" on page

50

).

Mirrored memory configuration

Mirroring provides protection against uncorrectable memory errors that would otherwise result in server

blade downtime.
Mirroring is performed on the branch level. Branch 0 and branch 1 mirror each other.
Each branch maintains a copy of all memory contents. Memory writes go to both branches. Memory

reads come from only one of the two branches (unless an uncorrectable error occurs). If a memory read

on one branch returns incorrect data due to an uncorrectable memory error, the system automatically

retrieves the proper data from the other branch. A branch is not necessarily disabled (thus losing

mirroring protection) because of a single uncorrectable error. Mirroring protection is not lost because of

transient and soft uncorrectable errors, resulting in systems that maintain mirroring protection (and thus

improved uptime) unless there is a failure of both branches.
In addition to general configuration requirements, mirrored memory FBDIMM configuration also has the

following requirements:

Banks A and B must be fully populated with FBDIMMs with identical part numbers.

Banks C and D must contain FBDIMMs with identical part numbers, if installed.

Banks E and F must contain FBDIMMs with identical part numbers, if installed.

For mirrored memory mode, populate the FBDIMM slots as specified in the following table:

Configuration

Bank A

1A, 4A

Bank B

7B, 10B

Bank C

2C, 5C

Bank D 8D,

11D

Bank E

3E, 6E

Bank F

9F, 12F

1

X X — — — —

2

X X X X — —

3

X X X X X X

After installing FBDIMMs, use RBSU to configure the system for mirrored memory support ("

Configuring

mirrored memory

" on page

50

).

Installing FBDIMMs

To install the component:

1.

Power down the server blade (on page

14

).

2.

Remove the server blade (on page

15

).

3.

Remove the access panel (on page

15

).

Advertising