Specifications, Switch specifications, Operating conditions – HP Storage EVA Capacity Upgrades User Manual

Page 41: A specifications, Aspecifications, Switch specifications operating conditions

Advertising
background image

30-10022-01 loop switch user guide

41

A

Specifications

Switch Specifications

Operating Conditions

The switch must be operated in a clean, dry environment with unrestricted airflow. Air flows in through
the cosmetic end and out through the business end (sometimes called the transceiver end or
“back-of-box”).

To avoid overheating, maintain a minimum clearance of two inches (50.8 millimeters) on each end of
the switch (the cosmetic end and the business end). Allow an adequate amount of space on the top
and sides of the switch for proper air ventilation. Do not place the switch on heat-generating surfaces.
Operating conditions are listed below.

Specification

Value

Number of Ports

12

Operating Rate

All ports operate independently at 1.0625 or 2.125 Gb/s

Port Media Type

SFP optical or copper based

Enclosure

1U half-rack form-factor

Management Interface

Fibre Channel, RS-232, or 10/100 Ethernet

EU Compliance

EU directive 2002/95/EC

Configurability

Management interface configurable

Power On Selftest (POST)

Yes

Dimensions

8.5" x 1.73" x 14.50" (W x H x D)

AC Power Input

50 or 60 Hz / 100 – 250 VAC / 1.0 – 0.5 A

AC Power Connector

IEC connector

Weight

Approximately 7 lbs.

Requirement

Value

Operating Temperature

0°C to 40°C normal operation (ambient air temperature)

Storage

-40°C to 80°C non-condensing

Power

50 or 60 Hz / 100 – 250 VAC / 1.0 – 0.5 A