Return Codes, Output Messages, and Error Codes
Hitachi Cache Manager User’s Guide
Error
Number
Error Message
Recommended Action
JSE204I-S
NOT ENOUGH SPACE IN
CACHE
This utility tried to reside the tracks specified by the BIND command, but there is not
enough cache memory.
(S) HRUDCRX terminates abnormally. (Return code is 12.)
(P) After releasing unnecessary resident area, execute the command again.
JSE205I-S
CACHE ACCESS IS
DISABLED
This utility tried to execute a BIND or DSMODE command, but the cache storage system is
disabled because of an unspecified failure.
(S) HRUDCRX terminates abnormally. (Return code is 12.)
(P) Use the STATUS command to check and print out the cache status, then call the Hitachi
Data Systems Technical Support Center.
JSE206I-S
UNABLE TO FIND ANY
ONLINE VOLUME IN
SUBSYSTEM
This utility could not find the specified online volume in the specified dataset. The volume
has the same storage system ID as one of the following:
1. the volume specified by the VOLUME parameter or the DDNAME parameter, or
2. the DKC parameter specified by the COUNTS command or the STATUS command.
(S) HRUDCRX terminates abnormally. (Return code is 12.)
(P) Vary the objective volume online, and execute the command again.
JSE207I-S
I/O ERROR ON [volume
serial number or disk
drive unit number]
An input / output error happened during the I/ O operation to the cache storage system.
(S) HRUDCRX terminates abnormally. (Return code is 12.)
(P) If there is an error message on another storage system, investigate and correct the
cause of the messages, then execute the command again.
JSE208I-E
‘volume serial number’ IS
NOT ONLINE
The volume specified by the VOLUME parameter is either not online, or not mounted in the
cache storage system.
(S) Terminate the command process, but the next process continues. (Return code is 8.)
(P) After varying the specified volume online, execute the command again.
JSE209I-S
COMMAND ‘command
name’ UNABLE TO
EXECUTE FOR DKC TYPE
‘disk controller type’
The disk drive unit does not support the specified command function.
(S) HRUDCRX terminates abnormally. (Return code is 12.)
(P) Execute the command again to the disk drive unit that belongs to the disk controller
with Cache Residency Manager installed.
JSE210I-S
COMMAND ‘command
name’ OPERAND
‘operand’ UNABLE TO
EXECUTE FOR DKC TYPE
‘disk controller type’
The disk drive unit does not support the specified command function. If this was a
DSMODE command, all operands are checked.
(S) HRUDCRX terminates abnormally. (Return code is 12.)
(P) Execute the command again to the disk drive unit that belongs to the disk storage
system with Cache Residency Manager installed.
JSE211I-S
CMG RECEIVED
UNEXPECTED RETURN
VALUE (RAID TYPE) ON
[volume serial number or
disk drive unit number]
HRUDCRX detected an unexpected failure during the execution of the I/O request to the
cache storage system. The cache storage system may have a malfunction.
(S) HRUDCRX terminates abnormally. (Return code is 12.)
(P) Call customer engineer and ask to investigate the disk storage system.
JSE213I-S
I/O ERROR OCCURRED
ON [volume serial
number, disk drive unit
number, sense byte]
An input / output error happened during the I/O operation to the cache storage system.
(S) HRUDCRX terminates abnormally. (Return code is 12.)
(P) Investigate and correct the specified error, then execute the command again.
JSE215I-E
‘disk drive unit number’
IS NOT FOUND
The specified disk drive unit number does not exist.
(S) Terminate the command process, but the next process continues. (Return code is 8.)
(P) Execute the command again by specifying the correct disk drive unit number.
JSE217I-E
‘disk drive unit number’
IS NOT MOUNTED ON
SYSTEM
The volume specified by disk drive unit number is not mounted.
(S) Terminate the command process, but the next process continues. (Return code is 8.)
(P) After mounting the volume specified by the disk drive unit number, execute the
command again.