HP ProLiant DL585 Server User Manual

Page 149

Advertising
background image

System LEDs and switches

HP ProLiant DL585 Server User Guide

E-13



Table E-10: QuickFind diagnostic display LEDs

continued

Item Description Status

Action

3 Processor

memory board

Off = Normal

On = Attention required

Processor memory board power failure. If
problem persists, replace the processor or
processor memory board.

4 Processor

power module

Off = Normal

On = Attention required

PPM power failure. If problem persists,
replace PPM.

If the PPM and the BRD LEDs are both on,
there is a configuration error.

5 Temperature

Off

=

Normal

On = Attention required

One or more components have
experienced an elevated temperature or a
thermal shutdown.

A thermal shutdown is indicated by the
Therm Trip LED.

•

Be sure the processor

heatsink is properly attached.

•

Be sure there are no 1.7"

DIMMs installed that prevent airflow
across the processor heatsink).

•

Be sure that all fans are

installed and working properly.

•

Be sure that the server

environment meets posted
requirements.

For information about server environment
requirements refer to the “Optimum
environment” section in Chapter 3.

6 DIMM

Off

=

Normal

On = Attention required

DIMM failure or configuration error. Refer to
the IML or POST messages

7

I/O power fault

Off = Normal

On = Attention required

A power fault on the system I/O board
occurred. If problem persists, replace the
system I/O board.