Troubleshooting
HP ProLiant DL585 Server User Guide
H-11
PPM or board power fault
Inspect the QuickFind diagnostic display
panel to determine if one of the PPMs,
processor memory boards, or system
board has experienced a power fault.
Ensure that all components are seated
properly.
If problem persists, replace the failed
component.
A PPM failure will be shown by the PPM
LED being illuminated on the specific
processor memory board.
If the processor memory board BRD LED
is amber, replace the processor memory
board.
If the I/O power LED is amber, replace the
system I/O board.
Thermal shutdown
If the Therm Trip LED is amber, the
system encountered an unexpected
thermal shutdown.
If one of the processor memory board
TEMP LEDs is amber, ensure that the
processor heatsink is properly attached,
all fans are functioning properly, and that
the external environment is within
specified parameters. Inspect the iLO logs
for any temperature-related warnings.
Yes
If the internal health LED is green, refer to
Table H-6.
Note: For LED locations and functions, refer to Appendix E, “System LEDs and switches.”